參數(shù)資料
型號: ADM1029ARQZ-R7
廠商: ON Semiconductor
文件頁數(shù): 12/50頁
文件大?。?/td> 402K
描述: IC SENSOR 2TEMP/FAN CTRL 24QSOP
產(chǎn)品變化通告: QSOP 24ld Pkg (MSL) Change 17/Jun/2010
標(biāo)準(zhǔn)包裝: 1,000
功能: 風(fēng)扇控制,溫度監(jiān)控器
傳感器類型: 內(nèi)部和外部
感應(yīng)溫度: 0°C ~ 100°C,外部傳感器
精確度: ±1°C 本地,±3°C 遠(yuǎn)程
拓?fù)洌?/td> ADC,風(fēng)扇控制,寄存器庫
輸出類型: 開路漏極
輸出警報:
輸出風(fēng)扇:
電源電壓: 3 V ~ 5.5 V
工作溫度: 0°C ~ 100°C
安裝類型: 表面貼裝
封裝/外殼: 24-SSOP(0.154",3.90mm 寬)
供應(yīng)商設(shè)備封裝: 24-QSOP
包裝: 帶卷 (TR)
ADM1029
http://onsemi.com
12
1. Place the ADM1029 as close as possible to the
remote sensing diode. Provided that the worst
noise sources such as clock generators,
data/address buses, and CRTs are avoided, this
distance can be 4 to 8 inches.
2. Route the D+ and D tracks close together, in
parallel, with grounded guard tracks on each side.
Provide a ground plane under the tracks if
possible.
3. Use wide tracks to minimize inductance and
reduce noise pickup. Ten mil track minimum
width and spacing is recommended.
Figure 22. Arrangement of Signal Tracks
10 MIL
10 MIL
10 MIL
10 MIL
10 MIL
10 MIL
10 MIL
GND
D
D+
GND
4. Try to minimize the number of copper/solder
joints, which can cause thermocouple effects.
Where copper/solder joints are used, make sure
that they are in both the D+ and D path and at the
same temperature.
Thermocouple effects should not be a major
problem as 1癈 corresponds to about 240 mV, and
thermocouple voltages are about 3 mV/癈 of
temperature difference. Unless there are two
thermocouples with a big temperature differential
between them, thermocouple voltages should be
much less than 200 mV.
5. Place 0.1 mF bypass and 1000 pF input filter
capacitors close to the ADM1029.
6. If the distance to the remote sensor is more than
8 inches, the use of twisted pair cable is
recommended. This will work up to about
6 to 12 feet.
7. For really long distances (up to 100 feet), use
shielded twisted pair such as Belden #8451
microphone cable. Connect the twisted pair to D+
and D and the shield to GND close to the
ADM1029. Leave the remote end of the shield
unconnected to avoid ground loops.
Because the measurement technique uses switched
current sources, excessive cable and/or filter capacitance
can affect the measurement. When using long cables, the
filter capacitor may be reduced or removed.
Cable resistance can also introduce errors. 1 W series
resistance introduces about 0.5癈 error.
Temperature-related Registers
Table 7 is a list of registers on the ADM1029 that are
specific to temperature measurement and control.
Table 7. TEMPERATURE-SPECIFIC REGISTERS
Address
Description
0x06
Temp Devices Installed
0x30
Local Temp Offset
0x31
Remote 1 Temp Offset
0x32
Remote 2 Temp Offset
0x40
Local Temp Fault Action
0x41
Remote 1 Temp Fault Action
0x42
Remote 2 Temp Fault Action
0x48
Local Temp Cooling Action
0x49
Remote 1 Temp Cooling Action
0x4A
Remote 2 Temp Cooling Action
0x80
Local Temp TMIN
0x81
Remote 1 Temp TMIN
0x82
Remote 2 Temp TMIN
0x88
Local Temp TRANGE/THYST
0x89
Remote 1 Temp TRANGE/THYST
0x8A
Remote 2 Temp TRANGE/THYST
0x90
Local Temp High Limit
0x91
Remote 1 Temp High Limit
0x92
Remote 2 Temp High Limit
0x98
Local Temp Low Limit
0x99
Remote 1 Temp Low Limit
0x9A
Remote 2 Temp Low Limit
0xA0
Local Temp Value
0xA1
Remote 1 Temp Value
0xA2
Remote 2 Temp Value
The flowchart in Figure 23 shows how to configure the
ADM1029 to measure temperature. It also shows how to
configure the ADM1029s behavior for out-of-limit
temperature measurements.
Fan Interfacing
The ADM1029 can be interfaced to many types of fan. It
can be used to control the speed of a simple two-wire fan. It
can measure the speed of a fan with a tach output, and it can
accept a logic input from fans with a FAULT output. By
means of a shorting link in the fan connector it can also
determine if a fan is present or not and if fans have been
hot-swapped.
The ADM1029 can control or monitor one or two fans.
Bits 0 and 1 of the Fans Supported In System Register (03h)
tell   the   ADM1029   how   many   fans   it   should   be
controlling/monitoring.
In the following descriptions installed means that the
corresponding bit of register 03h is set and the ADM1029
相關(guān)PDF資料
PDF描述
ADM1030ARQZ-RL7 IC SNSR TEMP/FAN PWM CTRL 16QSOP
ADM1032ARZ-REEL IC TEMP MONITOR 85DEG 8SOIC
ADM1033ARQZ-RL7 IC THERM/FAN SPEED CTLR 16-QSOP
ADM1034ARQZ-REEL IC THERM/FAN SPEED CTRLR 16-QSOP
ADN8810ACPZ-REEL7 IC CURRENT SOURCE(12BIT) 24LFCSP
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
ADM1030 制造商:AD 制造商全稱:Analog Devices 功能描述:Intelligent Temperature Monitor and PWM Fan Controller
ADM1030ARQ 功能描述:IC SNSR TEMP/FAN PWM CTRL 16QSOP RoHS:否 類別:集成電路 (IC) >> PMIC - 熱管理 系列:- 標(biāo)準(zhǔn)包裝:1 系列:- 功能:溫度監(jiān)控系統(tǒng)(傳感器) 傳感器類型:內(nèi)部和外部 感應(yīng)溫度:-40°C ~ 125°C,外部傳感器 精確度:±2.5°C 本地(最大值),±5°C 遠(yuǎn)程(最大值) 拓?fù)?ADC,比較器,寄存器庫 輸出類型:2 線 SMBus? 輸出警報:無 輸出風(fēng)扇:無 電源電壓:2.7 V ~ 5.5 V 工作溫度:-40°C ~ 125°C 安裝類型:表面貼裝 封裝/外殼:SOT-23-8 供應(yīng)商設(shè)備封裝:SOT-23-8 包裝:Digi-Reel® 其它名稱:296-22675-6
ADM1030ARQ-REEL 功能描述:IC SNSR TEMP/FAN PWM CTRL 16QSOP RoHS:否 類別:集成電路 (IC) >> PMIC - 熱管理 系列:- 標(biāo)準(zhǔn)包裝:1 系列:- 功能:溫度監(jiān)控系統(tǒng)(傳感器) 傳感器類型:內(nèi)部和外部 感應(yīng)溫度:-40°C ~ 125°C,外部傳感器 精確度:±2.5°C 本地(最大值),±5°C 遠(yuǎn)程(最大值) 拓?fù)?ADC,比較器,寄存器庫 輸出類型:2 線 SMBus? 輸出警報:無 輸出風(fēng)扇:無 電源電壓:2.7 V ~ 5.5 V 工作溫度:-40°C ~ 125°C 安裝類型:表面貼裝 封裝/外殼:SOT-23-8 供應(yīng)商設(shè)備封裝:SOT-23-8 包裝:Digi-Reel® 其它名稱:296-22675-6
ADM1030ARQ-REEL7 功能描述:IC SNSR TEMP/FAN PWM CTRL 16QSOP RoHS:否 類別:集成電路 (IC) >> PMIC - 熱管理 系列:- 標(biāo)準(zhǔn)包裝:1 系列:- 功能:溫度監(jiān)控系統(tǒng)(傳感器) 傳感器類型:內(nèi)部和外部 感應(yīng)溫度:-40°C ~ 125°C,外部傳感器 精確度:±2.5°C 本地(最大值),±5°C 遠(yuǎn)程(最大值) 拓?fù)?ADC,比較器,寄存器庫 輸出類型:2 線 SMBus? 輸出警報:無 輸出風(fēng)扇:無 電源電壓:2.7 V ~ 5.5 V 工作溫度:-40°C ~ 125°C 安裝類型:表面貼裝 封裝/外殼:SOT-23-8 供應(yīng)商設(shè)備封裝:SOT-23-8 包裝:Digi-Reel® 其它名稱:296-22675-6
ADM1030ARQZ 功能描述:馬達(dá)/運動/點火控制器和驅(qū)動器 TDM & PWM FAN CNTRLRS IC RoHS:否 制造商:STMicroelectronics 產(chǎn)品:Stepper Motor Controllers / Drivers 類型:2 Phase Stepper Motor Driver 工作電源電壓:8 V to 45 V 電源電流:0.5 mA 工作溫度:- 25 C to + 125 C 安裝風(fēng)格:SMD/SMT 封裝 / 箱體:HTSSOP-28 封裝:Tube