TNETA1555
155.52-MBIT/S CLOCK-RECOVERY DEVICE
SDNS001B – SEPTEMBER 1992 – REVISED DECEMBER 1994
2
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
Terminal Functions
TERMINAL
I/O
DESCRIPTION
NAME
NO.
CLK, CLK
20, 21
O
Recovered clock output. PECL compatible.
Capacitor connection for phase-locked-loop filter (CPLL = 0.1
μ
F recommended)
PECL-compatible input for PECL-to-ECL converter
CPLL
2
I
DATAIN, DATAIN,
14, 15
I
DATAOUT, DATAOUT
12, 13
O
ECL-compatible output for PECL converter
DIN, DIN
4, 6
I
Serial data input. PECL compatible.
DOUT, DOUT
18, 17
O
Serial data output. PECL compatible.
GND
3, 8, 10, 19
Ground (0-V reference)
INDIS
5
I
Input disable terminal (TTL compatible). The device ignores the input data when
INDIS is active and forces DOUT low and DOUT high.
TESTOUT
9
O
Manufacturing test output. Leave open.
TEST2
23
I
Manufacturing test input. Tied to GND.
TEST1
24
I
Manufacturing test input. Tied to GND.
VCC
1, 7, 11, 16, 22
Supply voltage
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage range, V
CC
(see Note 1)
Input voltage range, TTL
Input voltage range, ECL
Input voltage range, pseudo-ECL
Operating free-air temperature range, T
A
Storage temperature range, T
stg
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: All voltage values are with respect to the GND terminals.
–0.5 V to 7 V
–1.2 V to 7 V
–5.5 V to 0 V
0 V to 7 V
–40
°
C to 85
°
C
–65
°
C to 150
°
C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
recommended operating conditions
MIN
NOM
MAX
UNIT
VCC
VIH
VIL
IIK
VIH
VIL
TA
NOTE 2: The algebraic convention, in which the least positive (most negative) value is designated minimum, is used in this data sheet for
logic-level voltages only.
Supply voltage
4.75
5
5.25
V
High-level input voltage, TTL
2
V
Low-level input voltage, TTL
0.8
V
Input clamp current, TTL
–18
mA
High-level input voltage, PECL (see Note 2)
VCC–1.1
VCC–1.9
–40
VCC–0.8
VCC–1.5
V
Low-level input voltage, PECL (see Note 2)
V
°
C
Operating free-air temperature
85