OCTOBER 2000 - REVISED FEBRUARY 2005
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
TISP61089B High Voltage Ringing SLIC Protector
‘1089 Section 4.5.16 (Continued)
Dedicated intra-building ports may use an R
value of 8
. The 8
value limits the initial current to 13 A, which is within the TISP61089B
single cycle rating. For the TISP61089B to survive the full 900 s test, the series overcurrent protection to operate before the TISP61089B
current-time ratings are exceeded.
Overcurrent and Overvoltage Protection Coordination
To meet ‘1089, the overcurrent protection must be coordinated with the requirements of Sections 4.5.7, 4.5.8, 4.5.9, 4.5.12, 4.5.13, 4.5.15 and
the TISP61089B. The overcurrent protection must not fail in the first-level tests of Sections 4.5.7, 4.5.9 and 4.5.12 (tests 1 through 5). Test 6
through 9 of Section 4.5.12 are not requirements. The test current levels and their duration are shown in Figure 18. First-level tests have a high
source resistance and the current levels are not strongly dependent on the TISP61089B series resistor value.
Second-level tests have a low source resistance and the current levels are dependent on the TISP61089B R
S
resistor value. The two stepped
lines at the top of Figure 18 are for the 25
and 40
series resistor cases. The unacceptable current region (Section 4.5.11) is also shown in
Figure 18. If current flows for the full second-level test time, the unacceptable current region will be entered. The series overcurrent protector
must operate before the unacceptable region is reached.
MAXIMUM RMS CURRENT
vs
TIME
30
Second Level Tests, 25
Figure 18. ‘1089 Test Current Levels
Time - s
0.01
0.1
1
10
100
1000
M
0.1
0.2
0.3
0.5
0.7
1
2
3
5
7
10
20
AI6XAKB
Second Level
Tests, 40
First Level
Tests # 1
through 5,
25
& 40
Objective
First Level
Tests # 6
through 9
Unacceptable
Figure 19.
TISP61089B Overlay
PEAK AC
vs
CURRENT DURATION
t — Current Duration — s
0.01
0.1
1
10
100
1000
P
0.15
0.2
0.3
0.4
0.5
0.8
1.5
2
3
4
5
6
8
15
10
20
30
40
50
1
AI6XDM
Second Level
Tests, 40
Second Level
Tests, 25
Unacceptable
V
GG
= -60 V
First Level
Tests # 1
through 5,
25
& 40
V
GG
= -120 V
Fusible overcurrent protectors cannot operate at first-level current levels. Thus, the permissible low current time-current boundary for fusible
overcurrent protectors is formed by the first-level test currents. Automatically resettable overcurrent protectors (e.g. Positive Temperature
Coefficient Thermistors) may operate during first-level testing, but normal equipment working must be restored after the test has ended.
At system level, the high current boundary is formed by the unacceptable region. However, component and printed wiring, PW, current
limitations will typically lower the high current boundary. Although the series line feed resistance, R
S
, limits the maximum available current in
second-level testing, after about 0.5 s this limitation will exceed the acceptable current flow values.
These three boundaries, first-level, second-level and unacceptable, are replotted in terms of peak current rather than rms current values in
Figure 19. Using a peak current scale allows the TISP61089B longitudinal current rating curves (Figure 3) to be added to Figure 19. Assuming
the PW is sized to adequately carry any currents that may flow, the high current boundary for the overcurrent protector is formed by the
TISP61089B rated current. Note that the TISP61089B rated current curve also depends on the value of gate supply voltage.
相關(guān)PDF資料
PDF描述
TISP61089BDR TISP61089B High Voltage Ringing SLIC Protector
TISP61089BD-S TISP61089B High Voltage Ringing SLIC Protector
TISP61089BDR-S TISP61089B High Voltage Ringing SLIC Protector
TISP6L7591 DUAL FORWARD-CONDUCTING P-GATE THYRISTORS PROGRAMMABLE OVERVOLTAGE PROTECTORS
TISP6L7591DR-S DUAL FORWARD-CONDUCTING P-GATE THYRISTORS PROGRAMMABLE OVERVOLTAGE PROTECTORS
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
TISP61089BDR 功能描述:SCR Dual P Gate Forward Conducting RoHS:否 制造商:STMicroelectronics 最大轉(zhuǎn)折電流 IBO:480 A 額定重復(fù)關(guān)閉狀態(tài)電壓 VDRM:600 V 關(guān)閉狀態(tài)漏泄電流(在 VDRM IDRM 下):5 uA 開啟狀態(tài) RMS 電流 (It RMS): 正向電壓下降:1.6 V 柵觸發(fā)電壓 (Vgt):1.3 V 最大柵極峰值反向電壓:5 V 柵觸發(fā)電流 (Igt):35 mA 保持電流(Ih 最大值):75 mA 安裝風(fēng)格:Through Hole 封裝 / 箱體:TO-220 封裝:Tube
TISP61089BDR-S 功能描述:SCR Dual P Gate Forward Conducting RoHS:否 制造商:STMicroelectronics 最大轉(zhuǎn)折電流 IBO:480 A 額定重復(fù)關(guān)閉狀態(tài)電壓 VDRM:600 V 關(guān)閉狀態(tài)漏泄電流(在 VDRM IDRM 下):5 uA 開啟狀態(tài) RMS 電流 (It RMS): 正向電壓下降:1.6 V 柵觸發(fā)電壓 (Vgt):1.3 V 最大柵極峰值反向電壓:5 V 柵觸發(fā)電流 (Igt):35 mA 保持電流(Ih 最大值):75 mA 安裝風(fēng)格:Through Hole 封裝 / 箱體:TO-220 封裝:Tube
TISP61089BDR-T 功能描述:SCR PROTECTOR - PROGRAMMABLE SLIC PROTECT RoHS:否 制造商:STMicroelectronics 最大轉(zhuǎn)折電流 IBO:480 A 額定重復(fù)關(guān)閉狀態(tài)電壓 VDRM:600 V 關(guān)閉狀態(tài)漏泄電流(在 VDRM IDRM 下):5 uA 開啟狀態(tài) RMS 電流 (It RMS): 正向電壓下降:1.6 V 柵觸發(fā)電壓 (Vgt):1.3 V 最大柵極峰值反向電壓:5 V 柵觸發(fā)電流 (Igt):35 mA 保持電流(Ih 最大值):75 mA 安裝風(fēng)格:Through Hole 封裝 / 箱體:TO-220 封裝:Tube
TISP61089BDS 制造商:Bourns Inc 功能描述:
TISP61089BD-S 功能描述:SCR Dual P Gate Forward Conducting RoHS:否 制造商:STMicroelectronics 最大轉(zhuǎn)折電流 IBO:480 A 額定重復(fù)關(guān)閉狀態(tài)電壓 VDRM:600 V 關(guān)閉狀態(tài)漏泄電流(在 VDRM IDRM 下):5 uA 開啟狀態(tài) RMS 電流 (It RMS): 正向電壓下降:1.6 V 柵觸發(fā)電壓 (Vgt):1.3 V 最大柵極峰值反向電壓:5 V 柵觸發(fā)電流 (Igt):35 mA 保持電流(Ih 最大值):75 mA 安裝風(fēng)格:Through Hole 封裝 / 箱體:TO-220 封裝:Tube