(VDD, VDD1–VDD4 = 3.3 V, TA = 0 to 70 °C for K-Grade, –40 to 85 °C for B-Grade)
Parameter
Symbol
Test Condition
Min
Typ
Max
Unit
VDD1–VDD4
Supply Current
(Si3232)
IVDD1–IVDD4
Sleep mode, RESET = 0
—
1
—
mA
Open (high impedance)
—
15
—
mA
Active on-hook standby
—
15
—
mA
Forward/reverse active off-hook
ABIAS = 4 mA
—
20
—
mA
Forward/reverse active OHT
OBIAS = 4 mA
—
12 +
ILIM
—
mA
Ringing, VRING =45Vrms,
VBAT = –70 V, Sine Wave, 1 REN load —28—
mA
VDD Supply
Current (Si3200)
IVDD
Sleep mode, RESET = 0
—
100
—
A
Open (high impedance)
—
100
—
A
Active on-hook standby
—
110
—
A
Forward/reverse active off-hook,
ABIAS = 4 mA, VBAT =–24 V
—110
—
A
Forward/reverse OHT, OBIAS = 4 mA,
VBAT =–70 V
—110
—
A
Ringing, VRING =45Vrms,
VBAT = –70 V, Sine Wave, 7 REN load
—110
—
A
VBAT Supply
Current (Si3200)
IVBAT
Sleep mode, RESET = 0, VBAT =–70 V
—
100
—
A
Open (high impedance), VBAT = –70 V
—
225
—
A
Active on-hook standby, VBAT = –70 V
—
400
—
A
Forward/reverse active off-hook,
ABIAS = 4 mA, VBAT =–24 V
—
4.4 +
ILIM
—mA
Forward/reverse OHT, OBIAS = 4 mA,
VBAT =–70 V
—8.4
—
mA
Ringing, VRING =45Vrms,
VBAT = –70 V, Sine wave, 1 REN load
—6—
mA
Notes:
1. All specifications are for a single channel based on measurements with both channels in the same operating state.
3. Power consumption does not include additional power required for dc loop feed. Total system power consumption must
include an additional VBAT x ILIM term.