Reset settings = 0000_0000
Register 4. Interrupt Source
Bit
D7D6D5
D4D3D2
D1
D0
Name
RDTI
ROVI
FDTI
BTDI
DODI
LCSOI
DLCSI
POLI
Type
R/W
Bit
Name
Function
7RDTI
Ring Detect Interrupt.
0 = A ring signal is not occurring.
1 = A ring signal is detected. If the RDTM (Register 3) and INTE (Register 2) bits are set a hard-
ware interrupt occurs on the AOUT/INT pin. This bit must be written to a 0 to be cleared. The RDI
bit (Register 2) determines if this bit is set only at the beginning of a ring pulse, or at the end of a
ring pulse as well. This bit should be cleared after clearing the PDL bit (Register 6) because pow-
ering up the line-side device may cause this interrupt to be triggered.
6ROVI
Receive Overload Interrupt.
0 = An excessive input level on the receive pin is not occurring.
1 = An excessive input level on the receive pin is detected. If the ROVM and INTE bits are set a
hardware interrupt occurs on the AOUT/INT pin. This bit must be written to 0 to clear it. This bit is
identical in function to the ROV bit (Register 17). Clearing this bit also clears the ROV bit.
5FDTI
Frame Detect Interrupt
.
0 = Frame detect is established on the communications link.
1 = This bit is set when the communications link does not have frame lock. If the FDTM and INTE
bits are set, a hardware interrupt occurs on the AOUT/INT pin. Once set, this bit must be written
to a 0 to be cleared.
4BTDI
Billing Tone Detect Interrupt.
0 = A billing tone has not occurred.
1 = A billing tone has been detected. If the BTDM and INTE bits are set, a hardware interrupt
occurs on the AOUT/INT pin. This bit must be written to 0 to clear it.
3DODI
Drop Out Detect Interrupt
.
0 = The line-side power supply has not collapsed.
1 = The line-side power supply has collapsed (The DOD bit in Register 19 has fired). If the
DODM and INTE bits are set, a hardware interrupt occurs on the AOUT/INT pin. This bit must be
written to 0 to be cleared. This bit should be cleared after clearing the PDL bit (Register 6)
because powering as the line-side device can cause this interrupt to be triggered.
2LCSOI
Loop Current Sense Overload Interrupt
.
0 = The LCS bits have not reached max value (all ones).
1 = The LCS bits have reached max value. If the LCSOM bit (Register 3) and the INTE bit are
set, a hardware interrupt occurs on the AOUT/INT pin. This bit must be written to 0 to be cleared.
LCSOI does not necessarily imply that an overcurrent situation has occurred. An overcurrent sit-
uation in the DAA is determined by the status of the OPD bit (Register 19). After the LCSOI inter-
rupt fires, the OPD bit should be checked to determine if an overcurrent situation exists.
相關(guān)PDF資料
PDF描述
CW252016-82NG INDUCTOR 82NH 1008 SMD
SI3056PPT3-EVB BOARD EVAL FOR DAA SI3056/SI3008
SI3056DC3-EVB DAUGHTERCARD DAA SI3056/SI3008
CW252016-68NG INDUCTOR 68NH 1008 SMD
GCM22DSUI CONN EDGECARD 44POS DIP .156 SLD
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
Si3056SSI-EB 功能描述:撥號開發(fā)工具 Global DAA Standard Serial Interface EVB RoHS:否 制造商:Multi-Tech Systems 產(chǎn)品:Development Kits 類型:RJ Modems 工具用于評估:MT5656RJ 數(shù)據(jù)速率:115.2 kbps 接口類型:RJ-11, RS-232 工作電源電壓:3.3 V, 5 V
Si3056SSI-EVB 功能描述:界面開發(fā)工具 DAA Standard Serial Interface Eval Board RoHS:否 制造商:Bourns 產(chǎn)品:Evaluation Boards 類型:RS-485 工具用于評估:ADM3485E 接口類型:RS-485 工作電源電壓:3.3 V
SI3056-X-FS 制造商:SILABS 制造商全稱:SILABS 功能描述:GLOBAL SERIAL INTERFACE DIRECT ACCESS ARRANGEMENT
SI3060 制造商:未知廠家 制造商全稱:未知廠家 功能描述:GLOBAL LINE-SIDE DAA FOR EMBEDDED SYSTEM-SIDE MODULE
SI3060-X-FS 制造商:未知廠家 制造商全稱:未知廠家 功能描述:GLOBAL LINE-SIDE DAA FOR EMBEDDED SYSTEM-SIDE MODULE