STANDARD PRODUCT
PM7323 RCMP-200
DATASHEET
PMC-960543
ISSUE 2
ROUTING CONTROL, MONITORING, & POLICING
200 MBPS
Proprietary and Confidential to PMC-Sierra, Inc.
and for its Customer’s Internal Use.
123
Configuration register is a logic 1, VP-RM cells are further qualified by
PTI=110.
BADVCtoUP:
If the BADVCtoUP bit is a logic 1, all cells with an unprovisioned VPI/VCI are
routed to the Microprocessor Cell Interface for header logging.
DROPFRM:
If the DROPFRM bit is a logic 1, all forward RM cells are dropped (i.e. not
passed to the Output Cell Interface). Regardless of the state of this bit,
forward RM cells may be routed to the Microprocessor Cell Interface if the
FRMtoUP bit is set.
DROPBRM:
If the DROPBRM bit is a logic 1, all backward RM cells are dropped (i.e. not
passed to the Output Cell Interface). Regardless of the state of this bit,
backward RM cells may be routed to the Microprocessor Cell Interface if the
BRMtoUP bit is set.
DROPINVPTIVCI:
The DROPINVPTIVCI bit controls the dropping of VCC cells with an invalid
PTI and all VPC cells with an invalid VCI field. If DROPINVPTIVCI is a logic
1, all VCC cells with PTI='111' and all VPC cells with a VCI between7 through
15, inclusive, are not routed to the Output Cell Interface. If DROPINVPTIVCI
is a logic 0, these cells are passed transparently.
CCtoUP:
If the CCtoUP bit is a logic 1, all Continuity Check cells are copied to the
Microprocessor Cell Interface.
ACTDEtoOCIF:
If the ACTDEtoOCIF bit is a logic 1, all Activate/Deactivate cells are routed to
the Output Cell Interface. If ACTDEtoOCIF is 0, then at flow end-points, all
Activate/Deactivate cells are dropped. Regardless of the state of this bit, all
Activate/Deactivate cells are presented by the Output Cell Interface if the
RCMP-200 is not a flow end-point.