![](http://datasheet.mmic.net.cn/30000/M38507F8FP_datasheet_2360437/M38507F8FP_243.png)
3850 Group (Spec. H) User’s Manual
3-35
APPENDIX
3.3 Notes on use
Stop of transmit/receive operation
Clear the transmit enable bit and receive enable bit to “0” simultaneously (transmit and receive
disabled).
(when data is transmitted and received in the clock synchronous serial I/O mode, any one of data
transmission and reception cannot be stopped.)
q Reason
In the clock synchronous serial I/O mode, the same clock is used for transmission and reception.
If any one of transmission and reception is disabled, a bit error occurs because transmission and
reception cannot be synchronized.
In this mode, the clock circuit of the transmission circuit also operates for data reception. Accordingly,
the transmission circuit does not stop by clearing only the transmit enable bit to “0” (transmit
disabled). Also, the transmission circuit is not initialized by clearing the serial I/O1 enable bit to
“0” (Serial I/O1 disabled) (refer to (1) ).
SRDY1 output of reception side (Serial I/O1)
When signals are output from the SRDY1 pin on the reception side by using an external clock in the
clock synchronous serial I/O mode, set all of the receive enable bit, the SRDY1 output enable bit,
and the transmit enable bit to “1” (transmit enabled).
(2)
Notes when selecting clock asynchronous serial I/O (Serial I/O1)
Stop of transmission operation
Clear the transmit enable bit to “0” (transmit disabled).
q Reason
Since transmission is not stopped and the transmission circuit is not initialized even if only the
serial I/O1 enable bit is cleared to “0” (Serial I/O1 disabled), the internal transmission is running
(in this case, since pins TxD, RxD, SCLK1, and SRDY1 function as I/O ports, the transmission data
is not output). When data is written to the transmit buffer register in this state, data starts to be
shifted to the transmit shift register. When the serial I/O1 enable bit is set to “1” at this time, the
data during internally shifting is output to the TxD pin and an operation failure occurs.
Stop of receive operation
Clear the receive enable bit to “0” (receive disabled).
Stop of transmit/receive operation
Only transmission operation is stopped.
Clear the transmit enable bit to “0” (transmit disabled).
q Reason
Since transmission is not stopped and the transmission circuit is not initialized even if only the
serial I/O1 enable bit is cleared to “0” (Serial I/O1 disabled), the internal transmission is running
(in this case, since pins TxD, RxD, SCLK1, and SRDY1 function as I/O ports, the transmission data
is not output). When data is written to the transmit buffer register in this state, data starts to be
shifted to the transmit shift register. When the serial I/O1 enable bit is set to “1” at this time, the
data during internally shifting is output to the TxD pin and an operation failure occurs.
Only receive operation is stopped.
Clear the receive enable bit to “0” (receive disabled).