Skip condition
Datailed description
Carry
flag
CY
Rev.3.00
2004.08.06
page 137 of 155
REJ03B0010-0300Z
4584 Group
PRELIMINARY
Notice: This is not a final specification.
Some parametric limits are subject to change.
Skips the next instruction when the contents of bit 2 (V12) of interrupt control register V1 is “0” and the con-
tents of T1F flag is “1.” After skipping, clears (0) to T1F flag.
Skips the next instruction when the contents of bit 3 (V13) of interrupt control register V1 is “0” and the con-
tents of T2F flag is “1.” After skipping, clears (0) to T2F flag.
Skips the next instruction when the contents of bit 0 (V20) of interrupt control register V2 is “0” and the con-
tents of T3F flag is “1.” After skipping, clears (0) to T3F flag.
Skips the next instruction when the contents of bit 1 (V21) of interrupt control register V2 is “0” and the con-
tents of T4F flag is “1.” After skipping, clears (0) to T4F flag.
Transfers the input of port P0 to register A.
Outputs the contents of register A to port P0.
Transfers the input of port P1 to register A.
Outputs the contents of register A to port P1.
Transfers the input of port P2 to register A.
Outputs the contents of register A to port P2.
Transfers the input of port P3 to register A.
Outputs the contents of register A to port P3.
Transfers the input of port P4 to register A.
Outputs the contents of register A to port P4.
Transfers the input of port P5 to register A.
Outputs the contents of register A to port P5.
Transfers the input of port P6 to register A.
Outputs the contents of register A to port P6.
Sets (1) to all port D.
Clears (0) to a bit of port D specified by register Y.
Sets (1) to a bit of port D specified by register Y.
Skips the next instruction when a bit of port D specified by register Y is “0.” Executes the next instruction
when a bit of port D specified by register Y is “1.”
Clears (0) to port C.
Sets (1) to port C.
Transfers the contents of pull-up control register PU0 to register A.
Transfers the contents of register A to pull-up control register PU0.
Transfers the contents of pull-up control register PU1 to register A.
Transfers the contents of register A to pull-up control register PU1.
V12 = 0: (T1F) = 1
V13 = 0: (T2F) =1
V20 = 0: (T3F) = 1
V21 = 0: (T4F) =1
–
(D(Y)) = 0
However, (Y)=0 to 6
–