50
Altera Corporation
MAX 7000B Programmable Logic Device Family Data Sheet
Preliminary Information
Notes to tables:
(1)
These values are specified under the Recommended Operating Conditions in
Table 12 on page 25
.
(2)
MAX 7000B timing values are preliminary.
(3)
These values are specified for a PIA fan-out of one LAB (16 macrocells). For each additional LAB fan-out in these
devices, add an additional 0.1 ns to the PIA timing value.
(4)
Measured with a 16-bit loadable, enabled, up/ down counter programmed into each LAB.
(5)
The
f
MAX
values represent the highest frequency for pipelined data.
(6)
Operating conditions: V
CCIO
= 2.5
±
5
%
for commercial and industrial use.
(7)
The
t
LPA
parameter must be added to the
t
LAD
,
t
LAC
,
t
IC
,
t
ACL
,
t
CPPW
,
t
EN
, and
t
SEXP
parameters for macrocells
running in low-power mode.
Power
Consumption
Supply power (P) versus frequency (
f
MAX
, in MHz) for MAX 7000B
devices is calculated with the following equation:
P = P
INT
+ P
IO
= I
CCINT
×
V
CC
+ P
IO
The P
IO
value, which depends on the device output load characteristics
and switching frequency, can be calculated using the guidelines given in
Application Note 74 (Evaluating Power for Altera Devices)
.
The I
CCINT
value depends on the switching frequency and the application
logic. The I
CCINT
value is calculated with the following equation:
I
CCINT
=
(A
×
MC
TON
) + [B
×
(MC
DEV
– MC
TON
)] + (C
×
MC
USED
×
f
MAX
×
tog
LC
)
The parameters in this equation are:
Table 39. Selectable I/O Standard Output Adder Delays
I/O Standard
Speed Grade
Unit
-6
-7
-10
Min
Max
Min
Max
Min
Max
3.3 V TTL/CMOS
2.5 V TTL/CMOS
1.8 V TTL/CMOS
PCI
GTL+
SSTL-3 Class I
SSTL-3 Class II
SSTL-3 Class I
SSTL-3 Class II
0.0
0.2
1.3
0.0
-0.2
-0.1
-0.1
-0.1
-0.1
0.0
0.3
2.2
0.0
-0.3
-0.2
-0.2
-0.2
-0.2
0.0
0.4
2.9
0.0
-0.4
-0.2
-0.2
-0.2
-0.2
ns
ns
ns
ns
ns
ns
ns
ns
ns