![](http://datasheet.mmic.net.cn/160000/CX72302-11_datasheet_8625109/CX72302-11_14.png)
DATA SHEET CX72302
Skyworks Solutions, Inc. Phone [781] 376-3000 Fax [781] 376-3100 sales@skyworksinc.com www.skyworksinc.com
14
July 22, 2004 Skyworks Proprietary and Confidential information Products and Product Information are Subject to Change Without Notice 101216G
A3
A2 A1
A0 11
10
9
8
7
6
5
4
3
2
1
0
1
0
00
0
X
Reserved Bits
Modulation Data Magnitude Offset
Modulation Data Input Select
Modulation Address Disable
C1425
Figure 14. Modulation Control Register (Write Only)
A3
A2 A1
A0 11
10
9
8
7
6
5
4
3
2
1
0
10
01 MSB
LSB
Modulation Data Bits
C1426
Figure 15. Modulation Data Register (Write Only)
The Modulation Data Register is used to load the modulation data
samples to the modulation unit. This value is transferred to the
modulation unit on the falling edge of Fpd_main where it is passed to
the main
Σ modulator at the selected magnitude offset on the
next falling edge of Fpd_main. Modulation Data Register values are
2's complement format. As shown in Figure 15, the value to be
loaded is:
Modulation Data Bits = Modulation data samples that represent
the desired instantaneous frequency offset to the selected main
synthesizer frequency (selected channel) before being affected
by the modulation data magnitude offset.
Electrical and Mechanical Specifications
The CX72302 is supplied as a 28-pin EP-TSSOP. The exposed pad
is located on the bottom side of the package and must be
connected to ground for proper operation. The exposed pad
should be soldered directly to the circuit board.
Signal pin assignments and functional pin descriptions are
specified in Table 5. The absolute maximum ratings of the
CX72302 are provided in Table 6. The recommended operating
conditions are specified in Table 7 and electrical specifications
are provided in Table 8.
Figure 16 provides a schematic diagram for the CX72302.
Figure 17 shows the package dimensions for the 28-pin
EP-TSSOP and Figure 18 provides the tape and reel dimensions.
Electrostatic Discharge (ESD) Sensitivity
The CX72302 is a static-sensitive electronic device. Do not
operate or store near strong electrostatic fields. Take proper ESD