Mobile Pentium III Processor in BGA2 and Micro-PGA2 Packages Datasheet
Intel Corporation
18
Table 9. Power Specifications for Mobile Pentium III Processor with Intel SpeedStep Technology
1
TJ = 0°C to 100°C; VCC = 1.35V ±100 mV or 1.60V ±115 mV; V CCT = 1.50V ±115 mV
Symbol Parameter
Min
Typ
Max
Unit
Notes
VCC
Transient VCC for core logic
1.25
1.485
1.35
1.60
1.45
1.715
V
±100 mV
±115 mV, Note 7
VCC,DC
Static VCC for core logic
1.25
1.485
1.35
1.60
1.45
1.640
V
±100 mV
-115/+40 mV,
Note 2
VCCT
VCC for System Bus Buffers, Transient tolerance
1.385
1.50
1.615
V
±115 mV, Note 7
VCCT,DC
VCC for System Bus Buffers, Static tolerance
1.455
1.50
1.545
V
±3%, Note 2
ICC
Current for V CC at core frequency
at 500 MHz & 1.35V
at 600 MHz & 1.60V
at 650 MHz & 1.60V
9.5
12.6
13.6
A
Notes 4
ICCT
Current for V CCT
2.5
A
Notes 3, 4
ICC,SG
Processor Stop Grant and Auto Halt current
at 1.35V
at 1.60V
1.7
2.2
A
Notes 4
ICC,QS
Processor Quick Start and Sleep current
at 1.35V
at 1.60V
1.5
1.9
A
Note 4
ICC,DSLP
Processor Deep Sleep Leakage current
at 1.35V
at 1.60V
1.2
1.6
A
Notes 4
dICC/dt
VCC power supply current slew rate
1400
A/
s Notes 5, 6
dICCT/dt
VCCT power supply current slew rate
TBD
A/
s Notes 5, 6
NOTES:
1.
Unless otherwise noted, all specifications in this table apply to all processor frequencies. Processors with Intel SpeedStep
technology will comply with the ICCx,max specification for the current mode of operation.
2.
Static voltage regulation includes: DC output initial voltage set point adjust, output ripple and noise, output load ranges
specified in Table 9 above, temperature, and warm up.
3.
ICCT is the current supply for the system bus buffers, including the on-die termination.
4.
ICCx,max specifications are specified at VCC,DC max, VCCT,max, and 100°C and under maximum signal loading conditions.
5.
Based on simulations and averaged over the duration of any change in current. Use to compute the maximum inductance
and reaction time of the voltage regulator. This parameter is not tested.
6.
Maximum values specified by design/characterization at nominal VCC and VCCT.
7.
VCCx must be within this range under all operating conditions, including maximum current transients. VCCx must return to
within the static voltage specification, VCCx,DC, within 100
s after a transient event. The average of VCCx over time must
not exceed 1.65V, as an arbitrarily large time span may be used for this average.