ADM1031
http://onsemi.com
25
Table 15. Register 0y01 Configuration 2 PowerOn Default = 7FH
Bit
Name
R/W
Description
0
PWM 1 En
R/W
Enables Fan 1 PWM output when this bit is a “1.”
1
PWM 2 En
R/W
Enables Fan 2 PWM output when this bit is a “1.”
2
TACH 1 En
R/W
Enables Tach 1 input when set to “1.”
3
TACH 2 En
R/W
Enables Tach 2 input when set to “1.”
4
Loc Temp En
R/W
Enables Interrupts on local temperature channel when set to “1.”
5
Remote 1 Temp En
R/W
Interrupts on Remote 1 Channel when set to “1.” Default is normally enabled, except
when a diode fault is detected on powerup.
6
Remote 2 Temp En
R/W
Enables Interrupts on Remote 2 Channel when set to “1.” Default is normally enabled,
except when a diode fault is detected on powerup.
7
SW Reset
R/W
When set to “1,” resets the device. Selfclears. Powerup Default = 0.
Table 16. Register 0y02 Status Register 1 PowerOn Default = 00H
Bit
Name
R/W
Description
0
Alarm 1 Speed
R
This bit is set to “1” when fan is running at alarm speed. Once read, this bit is not
reasserted on next monitoring cycle, even if the fan is still running at alarm speed.
1
Fan 1 Fault
R
This bit is set to “1” if Fan 1 becomes stuck or is running under speed.
2
Remote 1 High
R
“1” indicates Remote 1 high temperature limit has been exceeded. If the temperature
is still outside the Remote 1 Temp High Limit, this bit reasserts on next monitoring
cycle.
3
Remote 1 Low
R
“1” indicates Remote 1 low temperature limit exceeded (below). If the temperature is
still outside the Remote 1 Temp Low Limit, this bit reasserts on next monitoring cycle.
4
Remote 1 THERM
R
“1” indicates Remote 1 temperature THERM limit has been exceeded. This bit is
cleared on a read of Status Register 1.
5
Remote Diode 1 Error
R
This bit is set to “1” if a short or open is detected on the Remote 1 temperature
channel. This test is only done on powerup, and if set to 1 cannot be cleared by
reading the Status Register 1.
6
Local Temp High
R
This bit is set to “1” if a short or open is detected on the Remote 1 temperature
channel. This test is only done on powerup, and if set to 1 cannot be cleared by
reading the Status Register 1.
7
Local Temp Low
R
“1” indicates Local Temp Low Limit has been exceeded (below). If the temperature is
still outside the Local Temp Low Limit, this bit reasserts on next monitoring cycle.
Table 17. Register 0y03 Status Register 2 Powerup Default = 00H
Bit
Name
R/W
Description
0
Alarm 2 Speed
R
This bit is set to “1” when Fan 2 is running at alarm speed. Once read, this bit is not
reasserted on next monitoring cycle, even if the fan is still running at alarm speed.
1
Fan 2 Fault
R
This bit is set to “1” if Fan 2 becomes stuck or is running under speed.
2
Remote 2 High
R
“1” indicates Remote 2 high temperature limit has been exceeded. If the temperature
is still outside the Remote 2 Temp High Limit, this bit reasserts on the next monitoring
cycle.
3
Remote 2 Low
R
“1” indicates Remote 2 low temperature limit exceeded (below). If the temperature is
still outside the Remote 2 Temp Low Limit, this bit reasserts on the next monitoring
cycle.
4
Remote 2 THERM
R
“1” indicates Remote 2 temperature THERM limit has been exceeded. This bit is
cleared on reading Status Register 2.
5
Remote Diode 2 Error
R
This bit is set to “1” if a short or open is detected on the Remote 2 temperature
channel. This test is only done on powerup, and if set to 1 cannot be cleared by
reading Status Register 2.
6
Local THERM
R
“1” indicates local temperature THERM limit has been exceeded. This bit clears on a
read of Status Register 2.
7
THERM
R
Set to “1” when THERM is pulled low as an input. This bit clears on a read of Status
Register 2.
相關(guān)PDF資料
PDF描述
ADM1031ARQZ-REEL DIGITAL TEMP SENSOR-SERIAL, 8BIT(s), 3Cel, RECTANGULAR, SURFACE MOUNT
ADM1031ARQZ-REEL7 DIGITAL TEMP SENSOR-SERIAL, 8BIT(s), 3Cel, RECTANGULAR, SURFACE MOUNT
ADM1031ARQZ DIGITAL TEMP SENSOR-SERIAL, 8BIT(s), 3Cel, RECTANGULAR, SURFACE MOUNT
ADM1031ARQ DIGITAL TEMP SENSOR-SERIAL, 11BIT(s), 3Cel, RECTANGULAR, SURFACE MOUNT
ADRF6604ACPZ-R7 2500 MHz - 2900 MHz RF/MICROWAVE DOUBLE BALANCED MIXER
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
ADM1031ARQZ-REEL 功能描述:板上安裝溫度傳感器 2 CH TDM PWM FAN CTRL IC RoHS:否 制造商:Omron Electronics 輸出類型:Digital 配置: 準(zhǔn)確性:+/- 1.5 C, +/- 3 C 溫度閾值: 數(shù)字輸出 - 總線接口:2-Wire, I2C, SMBus 電源電壓-最大:5.5 V 電源電壓-最小:4.5 V 最大工作溫度:+ 50 C 最小工作溫度:0 C 關(guān)閉: 安裝風(fēng)格: 封裝 / 箱體: 設(shè)備功能:Temperature and Humidity Sensor
ADM1031ARQZ-REEL7 功能描述:IC SENSOR 2TEMP/FAN CTRL 16QSOP RoHS:是 類別:集成電路 (IC) >> PMIC - 熱管理 系列:- 標(biāo)準(zhǔn)包裝:1 系列:- 功能:溫度監(jiān)控系統(tǒng)(傳感器) 傳感器類型:內(nèi)部和外部 感應(yīng)溫度:-40°C ~ 125°C,外部傳感器 精確度:±2.5°C 本地(最大值),±5°C 遠(yuǎn)程(最大值) 拓?fù)?ADC,比較器,寄存器庫(kù) 輸出類型:2 線 SMBus? 輸出警報(bào):無(wú) 輸出風(fēng)扇:無(wú) 電源電壓:2.7 V ~ 5.5 V 工作溫度:-40°C ~ 125°C 安裝類型:表面貼裝 封裝/外殼:SOT-23-8 供應(yīng)商設(shè)備封裝:SOT-23-8 包裝:Digi-Reel® 其它名稱:296-22675-6
ADM1032 制造商:AD 制造商全稱:Analog Devices 功能描述:+-1C Remote and Local System Temperature Monitor
ADM1032_12 制造商:ONSEMI 制造商全稱:ON Semiconductor 功能描述:1C Remote and Local System Temperature Monitor Supports SMBus Alert
ADM1032AR 功能描述:IC TEMP MONITOR 85DEG C 8SOIC RoHS:否 類別:集成電路 (IC) >> PMIC - 熱管理 系列:- 標(biāo)準(zhǔn)包裝:1 系列:- 功能:溫度監(jiān)控系統(tǒng)(傳感器) 傳感器類型:內(nèi)部和外部 感應(yīng)溫度:-40°C ~ 125°C,外部傳感器 精確度:±2.5°C 本地(最大值),±5°C 遠(yuǎn)程(最大值) 拓?fù)?ADC,比較器,寄存器庫(kù) 輸出類型:2 線 SMBus? 輸出警報(bào):無(wú) 輸出風(fēng)扇:無(wú) 電源電壓:2.7 V ~ 5.5 V 工作溫度:-40°C ~ 125°C 安裝類型:表面貼裝 封裝/外殼:SOT-23-8 供應(yīng)商設(shè)備封裝:SOT-23-8 包裝:Digi-Reel® 其它名稱:296-22675-6