22
PALCE22V10Z-25 (Com’l, Ind)
ABSOLUTE MAXIMUM RATINGS
Storage Temperature. . . . . . . . . . . . . .-65
°
C to +150
°
C
Ambient Temperature with
Power Applied . . . . . . . . . . . . . . . . . .-55
°
C to +125
°
C
Supply Voltage with Respect
to Ground . . . . . . . . . . . . . . . . . . . . .-0.5 V to +7.0 V
DC Input Voltage . . . . . . . . . . . .-0.5 V to V
CC
+ 0.5 V
DC Output or I/O Pin
Voltage . . . . . . . . . . . . . . . . . . .-0.5 V to V
CC
+ 0.5 V
Static Discharge Voltage . . . . . . . . . . . . . . . . . 2001 V
Latchup Current (T
A
= -40
°
C to +85
°
C) . . . . . .100 mA
Stresses above those listed under Absolute Maximum Ratings
may cause permanent device failure. Functionality at or above
these limits is not implied. Exposure to Absolute Maximum
Ratings for extended periods may affect device reliability.
Programming conditions may differ.
OPERATING RANGES
Commercial (C) Devices
Ambient Temperature (T
A
). . . . . . . . . . . 0
°C
to +75
°C
Supply Voltage (V
CC
) with
Respect to Ground. . . . . . . . . . . . . +4.75 V to +5.25 V
Industrial (I) Devices
Ambient Temperature (T
A
). . . . . . . . . -40
°C
to +85
°C
Supply Voltage (V
CC
) with
Respect to Ground. . . . . . . . . . . . . . . +4.5 V to +5.5 V
Operating ranges define those limits between which the func-
tionality of the device is guaranteed.
Notes:
1. These are absolute values with respect to device ground, and all overshoots due to system or tester noise are included.
2. Represents the worst case of HC and HCT standards, allowing compatibility with either.
3. I/O pin leakage is the worst case of I
IL
and I
OZL
(or I
IH
and I
OZH
).
4. Not more than one output should be shorted at a time, and the duration of the short-circuit should not exceed one second.
V
OUT
= 0.5 V has been chosen to avoid test problems caused by tester ground degradation.
DC CHARACTERISTICS OVER COMMERCIAL AND INDUSTRIAL OPERATING
RANGES
Parameter
Symbol
Parameter Description
Test Conditions
V
IN
= V
IH
or V
IL
V
CC
= Mn
Min
Max
Unit
V
OH
Output HIGH Voltage
I
OH
= -6 mA
I
OH
= -20
μ
A
I
OL
= 16 mA
I
OL
= 6 mA
I
OL
= 20
μ
A
3.84
V
V
CC
-0.1
V
V
OL
Output LOWVoltage
V
IN
= V
IH
or V
IL
V
CC
= Mn
0.5
V
0.33
V
0.1
V
V
IH
Input HIGH Voltage
Guaranteed Input Logical HIGH Voltage for all Inputs
(Notes 1, 2)
2.0
V
V
IL
Input LOWVoltage
Guaranteed Input Logical LOWVoltage for all Inputs
(Notes 1, 2)
0.9
V
I
IH
I
IL
I
OZH
I
OZL
I
SC
Input HIGH Leakage Current
V
IN
= V
CC
, V
CC
= Max (Note 3)
V
IN
= 0 V V
CC
= Max (Note 3)
V
OUT
= V
CC
, V
CC
= Max, V
IN
= V
IH
or V
IL
(Note 3)
V
OUT
= 0 V V
CC
= Max, V
IN
= V
IH
or V
IL
(Note 3)
V
OUT
= 0.5 V V
CC
= Max (Note 4)
Outputs Open (I
OUT
= 0 mA)
V
CC
= Max
10
μ
A
Input LOWLeakage Current
-10
μ
A
Off-State Output Leakage Current HIGH
10
μ
A
Off-State Output Leakage Current LOW
-10
μ
A
Output Short-Circuit Current
-5
-150
mA
I
CC
Supply Current
f = 0 MHz
30
μ
A
f = 15 MHz
120
mA