ABSOLUTE MAXIMUM RATINGS
Storage Temperature. . . . . . . . . . . . . .-65
°
C to +150
°
C
Ambient Temperature with
Power Applied . . . . . . . . . . . . . . . . . .-55
°
C to +125
°
C
Supply Voltage with Respect
to Ground . . . . . . . . . . . . . . . . . . . . .-0.5 V to +7.0 V
DC Input Voltage . . . . . . . . . . . .-0.5 V to V
CC
+ 1.0 V
DC Output or I/O Pin Voltage. . .-0.5 V to V
CC
+ 1.0 V
Static Discharge Voltage . . . . . . . . . . . . . . . . . 2001 V
Latchup Current (T
A
= 0
°
C to +75
°
C) . . . . . . . .100 mA
Stresses above those listed under Absolute Maximum Ratings
may cause permanent device failure. Functionality at or above
these limits is not implied. Exposure to Absolute Maximum
Ratings for extended periods may affect device reliability.
Programming conditions may vary.
OPERATING RANGES
Commercial (C) Devices
Ambient Temperature (T
A
)
Operating in Free Air. . . . . . . . . . . . . . . 0
°
C to +75
°
C
Supply Voltage (V
CC
) with
Respect to Ground. . . . . . . . . . . . . +4.75 V to +5.25 V
Operating ranges define those limits between which the func-
tionality of the device is guaranteed.
Notes:
1. These are absolute values with respect to the device ground, and all overshoots due to system and tester noise are included.
2. I/O pin leakage is the worst case of I
IL
and I
OZL
(or I
IH
and I
OZH
).
3. Not more than one output should be tested at a time. Duration of the short-circuit test should not exceed one second.
V
OUT
= 0.5 V has been chosen to avoid test problems caused by tester ground degradation.
DC CHARACTERISTICS OVER COMMERCIAL OPERATING RANGES
Symbol
Parameter Description
Test Conditions
Min
Max
Unit
V
OH
V
OL
Output HIGH Voltage
I
OH
= -3.2 mA, V
IN
= V
IH
or V
IL,
V
CC
= Mn
I
OL
= 16 mA, V
IN
= V
IH
or V
IL,
V
CC
= Mn
Guaranteed Input Logical HIGH
Voltage for all Inputs (Note 1)
2.4
V
Output LOWVoltage
0.4
V
V
IH
Input HIGH Voltage
2.0
V
V
IL
Input LOWVoltage
Guaranteed Input Logical LOW
Voltage for all Inputs (Note 1)
0.8
V
I
IH
I
IL
Input HIGH Leakage Current
V
IN
= V
CC
, V
CC
= Max (Note 2)
V
IN
= 0 V V
CC
= Max (Note 2)
10
μ
A
Input LOWLeakage Current
-100
μ
A
I
OZH
Off-State Output Leakage
Current HIGH
V
OUT
= V
CC
, V
CC
= Max, V
IN
= V
IL
or V
IH
(Note 2)
10
μ
A
I
OZL
Off-State Output Leakage
Current LOW
V
OUT
= 0 V V
CC
= Max, V
IN
= V
IL
or V
IH
(Note 2)
-100
μ
A
I
SC
Output Short-Circuit
Current
V
OUT
= 0.5 V VCC = Max
T
A
= 25°C (Note 3)
Outputs Open, (I
OUT
= 0 mA), V
CC
= Max
Outputs Open
,
(I
OUT
= 0 mA
),
V
CC
= Max, f = 25 MHz
-30
-130
mA
I
CC
(Static)
I
CC
(Dynamc)
Supply Current
115
mA
Supply Current
140
mA