XRD54L08/L10/L12
3
Rev. 1.30
ELECTRICAL CHARACTERISTICS
Test Conditions: VDD= 3V, GND= 0V, REFIN= 1.000V (External), RL= 10kW, CL= 100pF, TA= TMIN to TMAX,
Unless Otherwise Noted.
Symbol
Parameter
Min.
Typ.
Max.
Unit
Conditions
Static Performance XRD54L08
N
Resolution
8
Bits
INL
Relative Accuracy
0.25
0.5
LSB
DNL
Differential Nonlinearity
0.25
0.5
±LSB
Guaranteed Monotonic
VOS
Offset Error
0
3
8
mV
TCVOS
Offset Tempco
2
ppm/°C
PSRR
Offset-Error Power-Supply
Rejection Ratio
0.5
1
mV
2.5V ± VDD ± 3.5V
GE
Gain Error
0.1
0.4
%FS
TCGE
Gain-Error Tempco
10
ppm/°C
PSRR
Power-Supply
Rejection Ratio
0.1
1.25
mV
2.5V ± VDD ± 3.5V, Measured at
FS
Static Performance XRD54L10
N
Resolution
10
Bits
INL
Relative Accuracy
0.5
1
LSB
DNL
Differential Nonlinearity
0.50
0.75
±LSB
Guaranteed Monotonic
VOS
Offset Error
0
3
8
mV
TCVOS
Offset Tempco
2
ppm/°C
PSRR
Offset-Error Power-Supply
Rejection Ratio
0.5
1
mV
2.5V ± VDD ± 3.5V
GE
Gain Error
0.1
0.4
%FS
TCGE
Gain-Error Tempco
10
ppm/°C
PSRR
Power-Supply
Rejection Ratio
0.1
1.25
mV
2.5V ± VDD ± 3.5V, Measured at
FS
Static Performance XRD54L12
N
Resolution
12
Bits
INL
Relative Accuracy
2
4
LSB
DNL
Differential Nonlinearity
0.5
-1
LSB
Guaranteed Monotonic
1.25
LSB
VOS
Offset Error
0
3
8
mV
TCVOS
Offset Tempco
2
ppm/°C
PSRR
Offset-Error Power-Supply
Rejection Ratio
1.0
1.25
mV
2.5V ± VDD ± 3.5V
GE
Gain Error
0.1
0.4
%FS
TCGE
Gain-Error Tempco
10
ppm/°C
PSRR
Power-Supply
Rejection Ratio
0.1
1.25
mV
2.5V ± VDD ± 3.5V, Measured at
FS