參數(shù)資料
型號(hào): XR19L212IL48-0B-EB
廠商: Exar Corporation
文件頁數(shù): 26/52頁
文件大?。?/td> 0K
描述: EVAL BOARD FOR XR19L202 48QFN
標(biāo)準(zhǔn)包裝: 1
系列: *
XR19L212
32
TWO CHANNEL INTEGRATED UART AND RS-232 TRANSCEIVER
REV. 1.0.1
MCR[6]: Infrared Encoder/Decoder Enable (requires EFR bit-4=1)
Infrared mode should be used on channel B only. This bit should remain a logic 0 for channel A.
Logic 0 = Enable the standard modem receive and transmit input/output interface (default).
Logic 1 = Enable infrared IrDA receive and transmit inputs/outputs. The TX/RX output/input are routed to the
infrared encoder/decoder. The data input and output levels conform to the IrDA infrared interface
requirement. While in this mode, the infrared TX output will be idling LOW. SEE ”INFRARED MODE (UART
MCR[7]: Clock Prescaler Select (requires EFR bit-4=1)
Logic 0 = Divide by one. The input clock from the crystal or external clock is fed directly to the Programmable
Baud Rate Generator without further modification, i.e., divide by one (default).
Logic 1 = Divide by four. The prescaler divides the input clock from the crystal or external clock by four and
feeds it to the Programmable Baud Rate Generator, hence, data rates become one forth.
4.8
Line Status Register (LSR) - Read Only
This register provides the status of data transfers between the UART and the host.
LSR[0]: Receive Data Ready Indicator
Logic 0 = No data in receive holding register or FIFO (default).
Logic 1 = Data has been received and is saved in the receive holding register or FIFO.
LSR[1]: Receiver Overrun Error Flag
Logic 0 = No overrun error (default).
Logic 1 = Overrun error. A data overrun error condition occurred in the receive shift register. This happens
when additional data arrives while the FIFO is full. In this case the previous data in the receive shift register
is overwritten. Note that under this condition the data byte in the receive shift register is not transferred into
the FIFO, therefore the data in the FIFO is not corrupted by the error.
LSR[2]: Receive Data Parity Error Tag
Logic 0 = No parity error (default).
Logic 1 = Parity error. The receive character in RHR does not have correct parity information and is suspect.
This error is associated with the character available for reading in RHR.
LSR[3]: Receive Data Framing Error Tag
Logic 0 = No framing error (default).
Logic 1 = Framing error. The receive character did not have a valid stop bit(s). This error is associated with
the character available for reading in RHR.
LSR[4]: Receive Break Error Tag
Logic 0 = No break condition (default).
Logic 1 = The receiver received a break signal (RX was LOW for at least one character frame time). In the
FIFO mode, only one break character is loaded into the FIFO.
LSR[5]: Transmit Holding Register Empty Flag
This bit is the Transmit Holding Register Empty indicator. The THR bit is set to a logic 1 when the last data byte
is transferred from the transmit holding register to the transmit shift register. The bit is reset to logic 0
concurrently with the data loading to the transmit holding register by the host. In the FIFO mode this bit is set
when the transmit FIFO is empty, it is cleared when the transmit FIFO contains at least 1 byte.
相關(guān)PDF資料
PDF描述
VI-25M-EX CONVERTER MOD DC/DC 10V 75W
A3BKB-1018G IDC CABLE- ASR10B/AE10G/APK10B
VI-JVT-EZ-S CONVERTER MOD DC/DC 6.5V 25W
UPJ1K470MPD6TD CAP ALUM 47UF 80V 20% RADIAL
H3WWH-2406G IDC CABLE - HPL24H/AE24G/HPL24H
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
XR19L212IL48-F 功能描述:UART 接口集成電路 UART RoHS:否 制造商:Texas Instruments 通道數(shù)量:2 數(shù)據(jù)速率:3 Mbps 電源電壓-最大:3.6 V 電源電壓-最小:2.7 V 電源電流:20 mA 最大工作溫度:+ 85 C 最小工作溫度:- 40 C 封裝 / 箱體:LQFP-48 封裝:Reel
XR19L212IL48TR-F 制造商:Exar Corporation 功能描述:UART 2-CH 64Byte FIFO 5V 48-Pin QFN EP T/R 制造商:Exar Corporation 功能描述:XR19L212IL48TR-F
XR19L220 制造商:EXAR 制造商全稱:EXAR 功能描述:SINGLE CHANNEL INTEGRATED UART AND RS-232 TRANSCEIVER
XR19L220_07 制造商:EXAR 制造商全稱:EXAR 功能描述:SINGLE CHANNEL INTEGRATED UART AND RS-232 TRANSCEIVER
XR19L220IL40 制造商:EXAR 制造商全稱:EXAR 功能描述:SINGLE CHANNEL INTEGRATED UART AND RS-232 TRANSCEIVER