SM5009 series
NIPPON PRECISION CIRCUITS—12
5009AL series
3 V operation: V
DD
= 2.7 to 3.3 V, V
SS
= 0 V, Ta =
40 to 85
°
C unless otherwise noted.
Parameter
Symbol
Condition
Rating
Unit
min
typ
max
Output rise time
t
r1
Measurement cct 3, load cct 2, 0.1V
DD
to 0.9V
DD
, C
L
= 15 pF
–
3.5
9
ns
Measurement cct 3, load cct 2, 0.1V
DD
to 0.9V
DD
,
V
DD
= 2.3 to 2.7 V, Ta = –20 to +80
°
C, C
L
= 15 pF
–
4
13
t
r2
Measurement cct 3, load cct 2, 0.1V
DD
to 0.9V
DD
, C
L
= 30 pF
–
5
12
Measurement cct 3, load cct 2, 0.1V
DD
to 0.9V
DD
,
V
DD
= 2.3 to 2.7 V, Ta = –20 to +80
°
C, C
L
= 30 pF
–
5.5
16
Output fall time
t
f1
Measurement cct 3, load cct 2, 0.9V
DD
to 0.1V
DD
, C
L
= 15 pF
–
3.5
9
ns
Measurement cct 3, load cct 2, 0.9V
DD
to 0.1V
DD
,
V
DD
= 2.3 to 2.7 V, Ta = –20 to +80
°
C, C
L
= 15 pF
–
4
13
t
f2
Measurement cct 3, load cct 2, 0.9V
DD
to 0.1V
DD
, C
L
= 30 pF
–
5
12
Measurement cct 3, load cct 2, 0.9V
DD
to 0.1V
DD
,
V
DD
= 2.3 to 2.7 V, Ta = –20 to +80
°
C, C
L
= 30 pF
–
5.5
16
Output duty cycle
1
1. Determined by the lot monitor.
2. Oscillator stop function is built-in. When INH goes LOW, normal output stops. When INH goes HIGH, normal output is not resumed until after the
oscillator start-up time has elapsed.
Duty
Measurement cct 3, load cct 2, Ta = 25
°
C, V
DD
= 3 V,
f
≤
40 MHz, C
L
= 30 pF
45
–
55
%
Measurement cct 3, load cct 2, Ta = 25
°
C, V
DD
= 2.4 V,
f
≤
14.4 MHz, C
L
= 30 pF
40
–
60
CF5009AL
×
only, Measurement cct 3, load cct 2, Ta = 25
°
C,
V
DD
= 2.5 V, f
≤
30 MHz, C
L
= 15 pF
40
–
60
Output disable delay time
2
t
PLZ
Measurement cct 6, load cct 2, Ta = 25
°
C, V
DD
= 3 V, C
L
≤
15 pF
–
–
100
ns
Output enable delay time
2
t
PZL
–
–
100
ns
Maximum operating
frequency
f
max
Measurement cct 3
CF5009AL
×
40
–
–
MHz
SM5009AL
×
S
30
–
–
Measurement cct 3, Ta = –20 to +80
°
C
SM5009AL
×
S
40
–
–
Measurement cct 3, Ta = –20 to +80
°
C
V
DD
= 2.4 to 2.7 V,
SM5009AL
×
S
14.4
–
–
V
DD
= 2.3 to 2.7 V,
CF5009AL
×
30
–
–
V
DD
= 2.25 to 2.75 V,
CF5009AL
×
20
–
–