SM5009 series
NIPPON PRECISION CIRCUITS—11
Switching Characteristics
5009AH series
3 V operation: V
DD
= 2.7 to 3.3 V, V
SS
= 0 V, Ta =
20 to 80
°
C unless otherwise noted.
5 V operation: V
DD
= 4.5 to 5.5 V, V
SS
= 0 V, Ta =
40 to 85
°
C unless otherwise noted.
5009AK series
V
DD
= 4.5 to 5.5 V, V
SS
= 0 V, Ta =
40 to 85
°
C unless otherwise noted.
Parameter
Symbol
Condition
Rating
Unit
min
typ
max
Output rise time
t
r1
Measurement cct 3, load cct 2, 0.1V
DD
to 0.9V
DD
, C
L
= 15 pF
–
6
18
ns
Output fall time
t
f1
Measurement cct 3, load cct 2, 0.9V
DD
to 0.1V
DD
, C
L
= 15 pF
–
6
18
ns
Output duty cycle
1
1. Determined by the lot monitor.
Duty
Measurement cct 3, load cct 2, Ta = 25
°
C, V
DD
= 3 V, C
L
= 15 pF
45
–
55
%
Output disable delay time
t
PLZ
Measurement cct 6, load cct 2, Ta = 25
°
C, V
DD
= 3 V, C
L
≤
15 pF
–
–
100
ns
Output enable delay time
t
PZL
–
–
100
ns
Maximum operating
frequency
f
max
Measurement cct 3
16
–
–
MHz
Parameter
Symbol
Condition
Rating
Unit
min
typ
max
Output rise time
t
r1
Measurement cct 3, load cct 2, 0.1V
DD
to 0.9V
DD
, C
L
= 15 pF
–
4
12
ns
Output fall time
t
f1
Measurement cct 3, load cct 2, 0.9V
DD
to 0.1V
DD
, C
L
= 15 pF
–
4
12
ns
Output duty cycle
1
1. Determined by the lot monitor.
Duty
Measurement cct 3, load cct 2, Ta = 25
°
C, V
DD
= 5 V, C
L
= 15 pF
45
–
55
%
Output disable delay time
t
PLZ
Measurement cct 6, load cct 2, Ta = 25
°
C, V
DD
= 5 V, C
L
≤
15 pF
–
–
100
ns
Output enable delay time
t
PZL
–
–
100
ns
Maximum operating
frequency
f
max
Measurement cct 3
30
–
–
MHz
Parameter
Symbol
Condition
Rating
Unit
min
typ
max
Output rise time
t
r
Measurement cct 3, load cct 1, 0.4V to 2.4V, C
L
= 15 pF
–
2
6
ns
Output fall time
t
f
Measurement cct 3, load cct 1, 2.4V to 0.4V, C
L
= 15 pF
–
2
6
ns
Output duty cycle
1
1. Determined by the lot monitor.
Duty
Measurement cct 3, load cct 1, Ta = 25
°
C, V
DD
= 5 V, C
L
= 15 pF
45
–
55
%
Output disable delay time
t
PLZ
Measurement cct 6, load cct 1, Ta = 25
°
C, V
DD
= 5 V, C
L
≤
15 pF
–
–
100
ns
Output enable delay time
t
PZL
–
–
100
ns
Maximum operating
frequency
f
max
Measurement cct 3
Ta = –20 to +80
°
C
40
–
–
MHz
Ta = –40 to +85
°
C
30
–
–