NT6862-5xxxx
14
8. A/D Converters
The structure of these analog to digital converters is 6-bit
successive approximation. Analog voltage is supplied from
external sources to the A/D input pins and the result of the
conversion is stored in the 6-bit data latch registers ($0011
& $0014). The A/D channels are activated by clearing the
correspondent control bits in the ENADC control register.
When users write '0' to one of the enable control bits, its
correspondent I/O pin or DAC will be switched to the A/D
converter input pin (ADC0 & ADC1 shared with PORT10 &
PORT 11; ADC2 & ADC3 shared wit DAC0 & DAC1).
Conversion will be started by clearing CSTA bit
(CONVERSION START) in the ENADC control register.
When conversion is finished, system will set this INTADC
bit. Users can monitor this bit to get the valid A/D
conversion data in the AD latch registers ($0011 - $0014).
Users can also open interrupt sources to remind users to
get the stable digital data. Note that latched data is only
available at the activated A/D channel.
The analog voltage to be measured should be stabled
during the conversion operation and the variation will not
exceed LSB for the best accuracy in measurement.
Addr.
Register
INIT
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
R/W
$0010
ENADC
FFH
CSTA
-
-
-
ENADC3
ENADC2
ENADC1
ENADC0
W
$0011
AD0 REG
C0H
-
-
AD05
AD04
AD03
AD02
AD01
AD00
R
$0012
AD1 REG
00H
-
-
AD15
AD14
AD13
AD12
AD11
AD10
R
$0013
AD2 REG
00H
-
-
AD25
AD24
AD23
AD22
AD21
AD20
R
$0014
AD3 REG
00H
-
-
AD35
AD34
AD33
AD32
AD31
AD30
R
$001B
IEIRQ2
00H
-
-
-
-
INTADC
INTV
INTE1
INTMR
R/W
$001E
IRQ2
00H
-
-
-
-
INTADC
INTV
INTE1
INTMR
R
-
-
-
-
CLRADC
CLRV
CLRE1
CLRMR
W
Reference ADC Table
(V
DD
= 5.0V)
15
1.53V
1C
2.07V
23
2.62V
2A
3.16V
16
1.62V
1D
2.16V
24
2.70V
2B
3.25V
17
1.69V
1E
2.23V
25
2.77V
2C
3.33V
18
1.76V
1F
2.31V
26
2.85V
2D
3.40V
19
1.84V
20
2.39V
27
2.93V
2E
3.48V
1A
1.92V
21
2.47V
28
3.01V
2F
3.56V
1B
2.00V
22
2.54V
29
3.09V
30
3.64V
Note: It is strongly recommended that the ADC’ s input signal should be allocated in the ADC’ s linear voltage range
(1.5V - 3.5V) to obtain a stable digital value. Do not use the outer ranges (0V - 1.4V & 3.6V - 5.0V) in which the