AT32UC3L016/32/64
35.2.8
SPI
1.
SPI data transfer hangs with CSR0.CSAAT==1 and MR.MODFDIS==0
When CSR0.CSAAT==1 and mode fault detection is enabled (MR.MODFDIS==0), the SPI
module will not start a data transfer.
Fix/Workaround
Disable mode fault detection by writing a one to MR.MODFDIS.
2.
Disabling SPI has no effect on the SR.TDRE bit
Disabling SPI has no effect on the SR.TDRE bit whereas the write data command is filtered
when SPI is disabled. Writing to TDR when SPI is disabled will not clear SR.TDRE. If SPI is
disabled during a PDCA transfer, the PDCA will continue to write data to TDR until its buffer
is empty, and this data will be lost.
Fix/Workaround
Disable the PDCA, add two NOPs, and disable the SPI. To continue the transfer, enable the
SPI and PDCA.
3.
SPI disable does not work in SLAVE mode
SPI disable does not work in SLAVE mode.
Fix/Workaround
Read the last received data, then perform a software reset by writing a one to the Software
Reset bit in the Control Register (CR.SWRST).
4.
SPI bad serial clock generation on 2nd chip_select when SCBR=1, CPOL=1, and
NCPHA=0
When multiple chip selects (CS) are in use, if one of the baudrates equal 1 while one
(CSRn.SCBR=1) of the others do not equal 1, and CSRn.CPOL=1 and CSRn.NCPHA=0,
then an additional pulse will be generated on SCK.
Fix/Workaround
When multiple CS are in use, if one of the baudrates equals 1, the others must also equal 1
if CSRn.CPOL=1 and CSRn.NCPHA=0.
5.
SPI mode fault detection enable causes incorrect behavior
When mode fault detection is enabled (MR.MODFDIS==0), the SPI module may not operate
properly.
Fix/Workaround
Always disable mode fault detection before using the SPI by writing a one to MR.MODFDIS.
35.2.9
TWI
1.
TWIM SR.IDLE goes high immediately when NAK is received
When a NAK is received and there is a non-zero number of bytes to be transmitted,
SR.IDLE goes high immediately and does not wait for the STOP condition to be sent. This
does not cause any problem just by itself, but can cause a problem if software waits for
SR.IDLE to go high and then immediately disables the TWIM by writing a one to CR.MDIS.
Disabling the TWIM causes the TWCK and TWD pins to go high immediately, so the STOP
condition will not be transmitted correctly.
Fix/Workaround
If possible, do not disable the TWIM. If it is absolutely necessary to disable the TWIM, there
must be a software delay of at least two TWCK periods between the detection of
SR.IDLE==1 and the disabling of the TWIM.
2.
TWIM TWALM polarity is wrong