MC10E016, MC100E016
http://onsemi.com
5
Table 7. 10E SERIES NECL DC CHARACTERISTICS VCCx = 0.0 V; VEE = 5.0 V (Note 3)
0°C
25°C
85°C
Symbol
Characteristic
Min
Typ
Max
Min
Typ
Max
Min
Typ
Max
Unit
IEE
Power Supply Current
151
181
151
181
151
181
mA
VOH
Output HIGH Voltage (Note 4)
1020
930
840
980
895
810
910
815
720
mV
VOL
Output LOW Voltage (Note 4)
1950 1790 1630 1950 1790 1630 1950 1773 1595
mV
VIH
Input HIGH Voltage
1170 1005
840
1130
970
810
1060
890
720
mV
VIL
Input LOW Voltage
1950 1715 1480 1950 1715 1480 1950 1698 1445
mV
IIH
Input HIGH Current
150
mA
IIL
Input LOW Current
0.5
0.3
0.5
0.065
0.3
0.2
mA
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification
limit values are applied individually under normal operating conditions and not valid simultaneously.
3. Input and output parameters vary 1:1 with VCC. VEE can vary 0.46 V / +0.06 V.
4. Outputs are terminated through a 50 W resistor to VCC 2.0 V.
Table 8. 100E SERIES PECL DC CHARACTERISTICS VCCx = 5.0 V; VEE = 0.0 V (Note 5)
Symbol
Characteristic
0°C
25°C
85°C
Unit
Min
Typ
Max
Min
Typ
Max
Min
Typ
Max
IEE
Power Supply Current
151
181
151
181
174
208
mA
VOH
Output HIGH Voltage (Note 6)
3975
4050
4120
3975
4050
4120
3975
4050
4120
mV
VOL
Output LOW Voltage (Note 6)
3190
3295
3380
3190
3255
3380
3190
3260
3380
mV
VIH
Input HIGH Voltage
3835
3975
4120
3835
3975
4120
3835
3975
4120
mV
VIL
Input LOW Voltage
3190
3355
3525
3190
3355
3525
3190
3355
3525
mV
IIH
Input HIGH Current
150
mA
IIL
Input LOW Current
0.5
0.3
0.5
0.25
0.5
0.2
mA
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification
limit values are applied individually under normal operating conditions and not valid simultaneously.
5. Input and output parameters vary 1:1 with VCC. VEE can vary 0.46 V / +0.8 V.
6. Outputs are terminated through a 50 W resistor to VCC 2.0 V.