BCD20001-G Rev AB
Page 21 of 28
www.power-one.com
K Series with PFC Data Sheet
150 – 280 Watt AC-DC Converters
Fig. 31
Schematic safety concept.
AC-DC
con-
verter
Mains
SELV
Earth connection
+
–
~
10021a
Fuse
Description of Options
Table 19: Survey of options
Option
Function of option
Characteristic
-9
Extended operational ambient temperature range
TA = – 40 to 71 °C
E
Electronic inrush current limitation circuitry
Active inrush current limitation
P2
Potentiometer for fine adjustment of output voltage
Adjustment range +10/ – 60% of Vo nom, excludes R input
D1
Input and/or output undervoltage monitoring circuitry
Safe data signal output (D0 – DD)
V1
Input and/or output undervoltage monitoring circuitry
ACFAIL signal according to VME specifications (V0, V2, V3)
T
Current sharing
Interconnect T-pins if paralleling outputs (max 5 converters)
K
H15S4 connector for 5.1 V output models
For new designs; provides compatibility with LK1001 models
B1, B2
Cooling plate (160 or 220 mm long)
Replaces standard heat sink, allowing direct chassis-mounting
1
Option D excludes option V and vice versa; option V only for 5.1 V outputs.
2
Option P is not available for battery charger models.
Table 17: Isolation
Characteristic
Input to case
Output(s) to
Output 1 to
Unit
and output(s)
case
output 2
Electric
Factory test >1 s
2.8 1
1.4
0.15
kVDC
strength
AC test voltage equivalent
2.0
1.0
0.1
kVAC
test
to factory test
Insulation resistance at 500 VDC
>300
>100 2
M
Creapage distances
≥ 3.2 3
--
mm
1
According to EN 50116 and IEC/EN 60950, subassemblies connecting input to output are pre-tested with 5.6 kVDC or 4 kVAC.
2
Tested at 150 VDC
3
Input to outputs: 6.4 mm
-9 Extended Temperature Range
Option -9 extends the operational ambient temperature
range from –25 to 71 °C (standard) to – 40 to 71 °C. The
power supplies provide full nominal output power with
convection cooling. Option -9 excludes inrush current
limitation by NTC.
E Inrush Current Limitation
The converters may be supplemented by an electronic
circuit replacing the standard built-in NTC to achieve an
enhanced inrush current limiting function.
Note: Subsequent switch-on cycles at start-up are limited to
max. 10 cycles during the first 20 seconds (cold converter) and
then to max. 1 cycle every 8 s.
will not honor any warranty claims resulting from electric
strength field tests.
Safety of Operator-Accessible Output Circuits
If the output circuit of a converter is operator-accessible, it
shall be an SELV circuit according to IEC/EN 60950.
The table below shows a possible installation configuration,
compliance with which causes the output circuit of a K Series
AC-DC converter to be a SELV circuit according to IEC/EN
60950 up to a configured output voltage of 36 V (sum of
nominal voltages connected in series) .
However, it is the sole responsibility of the installer to
ensure compliance with the applicable safety regulations.
Table 18: Safety concept leading to a SELV output circuit
Conditions
AC-DC converter
Installation
Result
Nominal voltage
Grade of insulation
Measures to achieve the resulting
Safety status of the AC-DC
between input and output
safety status of the output circuit
converter output circuit
provided by the AC-DC converter
Mains
Double or reinforced
Earthed case1 and installation
SELV circuit
≤ 250 VAC
according to the applicable standards
1 The earth connection has to be provided by the installer according to the relevant safety standards, e.g. IEC/EN 60950.