P
P
- 9 - 
 Andigilog, Inc. 2006 
www.andigilog.com
October 2006 - 70A05007 
aSC7611
In this way, up to three aSC7611 devices can exists on a 
SMBus at any time.  Multiple aSC7611 devices can be 
used to monitor additional processors in the temperature 
zones.  When using the non-default addresses, additional 
circuitry will be required if Tach4 and PWM3 require to 
function correctly.  Such circuitry could consist of GPIO 
pins from a micro-controller.  During the first 
communication the micro-controller would drive the 
 AddressEnable
  and Address Select pins to the proper 
state for the required address.  After the first SMBus 
communication the micro-controller would drive its pins into 
Tri-State allowing TACH4 and PWM3 to operate correctly. 
Writing to and Reading from the aSC7611 
All read and write operations must begin with a start 
condition generated by the master device.  After the start 
condition, the master device must immediately send a 
slave address (7-bits) followed by a R/
 W
 bit.  If the slave 
address matches the address of the aSC7611, it sends an 
ACK by pulling the SDA line low for one clock. Read or 
write operations may contain one- or two-bytes. See 
Figures 2 through 6 for timing diagrams for all aSC7611 
operations. 
Setting the Register Address Pointer 
For all operations, the address pointer stored in the 
address pointer register must be pointing to the register 
address that is going to be written to or read from. This 
register’s content is automatically set to the value of the 
first byte following the R/
 W
 bit being set to 0.    
After the aSC7611 sends an ACK in response to receiving 
the address and R/
 W
 bit, the master device must transmit 
an appropriate 8-bit address pointer value as explained in 
the Registers section of this data sheet. The aSC7611 will 
send an ACK after receiving the new pointer data.   
The register address pointer set operation is illustrated in 
Figure 2. If the address pointer is not a valid address the 
aSC7611 will internally terminate the operation.  Also recall 
that the address register retains the current address pointer 
value between operations.  Therefore, once a register is 
being pointed to, subsequent read operations do not 
require another Address Pointer set cycle. 
Writing to Registers 
All writes must start with a pointer set as described 
previously, even if the pointer is already pointing to the 
desired register. The sequence is described in Figure 2. 
Immediately following the pointer set, the master must 
begin transmitting the data to be written. After transmitting 
each byte of data, the master must release the SDA line for 
one clock to allow the aSC7611 to acknowledge receiving 
the byte. The write operation should be terminated by a 
stop condition from the master. 
Reading from Registers 
To read from a register other than the one currently being 
pointed to by the address pointer register, a pointer set 
sequence to the desired register must be done as 
described previously.  Immediately following the pointer 
set, the master must perform a repeat start condition that 
indicates to the aSC7611 that a read is about to occur. It is 
important to note that if the repeat start condition does not 
occur, the aSC7611 will assume that a write is taking place, 
and the selected register will be overwritten by the 
upcoming data on the data bus. The read sequence is 
described in Figure 4. After the start condition, the master 
must again send the device address and read/write bit. 
This time the R/
 W
 bit must be set to 1 to indicate a read. 
The rest of the read cycle is the same as described in the 
previous paragraph for reading from a preset pointer 
location.  
If the pointer is already pointing to the desired register, the 
master can read from that register by setting the R/
 W
 bit 
(following the slave address) to a 1.  After sending an ACK, 
the aSC7611 will begin transmitting data during the 
following clock cycle. After receiving the 8 data bits, the 
master device should respond with a NACK followed by a 
stop condition.  
If the master is reset while the aSC7611 is in the process of 
being read, the master should perform an SMBus reset. 
This is done by holding the data or clock low for more than 
35ms, allowing all SMBus devices to be reset. This follows 
the SMBus 2.0 specification of 25-35ms. 
When the aSC7611 detects an SMBus reset, it will prepare 
to accept a new start sequence and resume 
communication from a known state.