112, 112-PGF
2.34
2.80
3.25
4.40
5.50
6.90
9.10
10.8
13.1
20.6
26.5
30.0
35.0
45.5
49.0
72.0
95.0
122
146
190
230
Minimum
Voltage
0.18
0.22
0.27
0.34
0.41
0.55
0.68
0.86
1.09
1.37
1.72
2.11
2.77
3.46
4.33
5.47
7.11
8.53
10.8
14.1
17.7
390
310
250
200
160
114
910
83.0
69.0
50.0
42.0
35.0
26.0
22.0
16.4
13.0
10.2
8.5
6.5
4.9
4.9
6
9
13
22
34
60
100
130
190
370
630
860
1,350
2,070
3,000
6,500
9,230
14,300
22,500
38,500
53,000
323
260
211
165
133
95.0
76.0
69.0
57.0
42.0
35.0
29.0
22.0
18.0
14.0
11.0
8.5
7.0
5.5
4.0
3.5
0.55
0.84
1.26
2.10
3.10
5.80
9.00
12.5
19.0
33.0
50.0
74.0
1219
197
312
504
840
1,220
1,990
3,450
5,050
DC COILS
Minimum
Milliamps
AC COILS, 50/60 HZ
Minimum
Milliamps
Voltage
COIL SPECIFICATIONS
Measured @ 25C
Minimum
Voltage
1.0
1.4
1.6
2.0
2.5
3.5
4.3
5.0
6.0
8.5
12.0
13.5
16.
20
23
33
43
55
67
87
103
130
146
168
225
Minimum
Milliamps
177
143
116
91.0
74.0
52.5
41.5
38.0
31.5
23.0
19.0
15.7
11.8
9.65
7.65
6.00
4.66
3.85
2.98
2.25
1.93
1.53
1.22
0.95
0.74
Impedance
Ohms
6
9
13
22
34
60
100
130
190
370
630
860
1,350
2,070
3,000
6,500
9,230
14,300
22,500
38,500
53,000
85,000
120,600
177,000
300,000
Minimum
Voltage
0.08
0.10
0.12
0.15
0.19
0.25
0.30
0.39
0.49
0.62
0.78
0.95
1.30
1.60
2.00
2.50
3.20
3.90
4.80
6.40
8.00
9.70
11.7
16.0
21.0
Resistance
Ohms
0.55
0.84
1.26
2.10
3.10
5.80
9.00
12.5
19.0
33.0
50.0
74.0
129
197
312
504
840
1,220
1,990
3,450
5,050
7,700
11,700
19,000
34,000
AC COILS, 50/60 HZ
DC COILS
Minimum
Milliamps
145
117
95.0
73.0
60.0
43.0
33.0
31.0
26.0
18.8
15.5
12.8
9.70
7.90
6.30
4.90
3.80
3.15
2.43
1.84
1.58
1.25
1.00
0.84
0.61
LOAD
AC
DC
2A
-
240VAC
CONTACT RATINGS
Min. Voltage:
Min. Current:
Series Coils:
SERIES
2 AMP, LOW COIL POWER, 1 & 2 POLE PLUG-IN
PAGE 188
WEBSITE: www.magnecraft.com EMAIL:info@magnecraft.com FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
Selected from coil tables
Selected from coil tables
Available for connection in
series with loads up to 50
Amps for series 112, and
10 Amps for series 112-PGF.
OPERATING DATA:
(All Types)
TYPES 112XBX, 112XBXPGF
TYPES A112XAX, 112XAXPGF
Resistance
Ohms
Impedance
Ohms
Minimum
30VDC
2A
2A
2A
0.25A
120VAC
Approvals for
A112XAX & XBX Only.
UL Recognized
File No. E7104
COIL
Overvoltage, max.
CONTACTS
Contact Material:
TIMING
Operate Time:
Release Time:
DIELECTRIC STRENGTH
Across open contacts:
All Mutually Insulated
current carrying parts to
ground:
TEMPERATURE
Rated Operation:
LIFE EXPECTANCY
Mechanical:
Electrical:
MISCELLANEOUS
Enclosure:
Weight:
AC, 5 x min. voltage,
DC, 10 x min. voltage (up to 300V)
Fine Silver
20 mS Max. @ Nominal Voltage.
20 mS Max. @ Nominal Voltage.
500 V rms
1500 V rms
-45C to +65C
500,000 Operations no load
100,000 Operations @ Rated Load.
Clear polycarbonate. (112-PGF Only)
7.05 oz. (200 g) approx.
GENERAL SPECIFICATIONS 112, 112-PGF