www.ti.com
ABSOLUTE MAXIMUM RATINGS
(1)
RECOMMENDED OPERATING CONDITIONS
SUPPLY CURRRENT
over operating free-air temperature range (unless otherwise noted)
DEVICE SWITCHING CHARACTERISTICS
over recommended operating conditiions (unless otherwise noted)
SN65HVD1040
SLLS631B–MARCH 2007–REVISED APRIL 2007
VALUE
–0.3 V to 7 V
–27 V to 40 V
-20 mA to 20 mA
–200 V to 200 V
±
12 kV
±
4 kV
±
1 kV
±
200 V
–0.5 V to 6 V
–55
°
C to 170
°
C
V
CC
V
I(bus)
I
O(OUT)
Supply voltage
(2)
Voltage range at any bus terminal (CANH, CANL, SPLIT)
Receiver output current
Voltage input, transient pulse
(3)
, (CANH, CANL, SPLIT)
Human Body Model
Human body model
(4)
Charged-device-model
(5)
Machine model
Voltage input range (TXD, STB)
Junction temperature
Bus terminals and GND
All pins
All pins
ESD
V
I
T
J
(1)
Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings
only and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating
conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
All voltage values, except differential I/O bus voltages, are with respect to network ground terminal.
Tested in accordance with ISO 7637, test pulses 1, 2, 3a, 3b, 5, 6 & 7.
Tested in accordance JEDEC Standard 22, Test Method A114-A.
Tested in accordance JEDEC Standard 22, Test Method C101.
(2)
(3)
(4)
(5)
MIN
4.75
–12
(1)
NOM
MAX
5.25
UNIT
V
V
V
V
V
V
CC
V
I
or V
IC
V
IH
V
IL
V
ID
Supply voltage
Voltage at any bus terminal (separately or common mode)
High-level input voltage
Low-level input voltage
Differential input voltage
12
2
0
5.25
0.8
TXD, STB
–6
6
Driver
Receiver
Driver
Receiver
–70
–2
I
OH
High-level output current
mA
70
2
0.7
150
I
OL
Low-level output current
mA
t
SS
T
J
Maximum pulse width to remain in standby
Junction temperature
μ
s
C
–40
(1)
The algebraic convention, in which the least positive (most negative) limit is designated as minimum is used in this data sheet.
PARAMETER
TEST CONDITIONS
MIN
TYP
50
MAX
UNIT
Dominant
Recessive
Standby
V
I
= 0 V, 60
Load, STB at 0 V
V
I
= V
CC
, STB at 0 V
STB at VCC, VI = VCC
70
10
12
mA
I
CC
Supply current, V
CC
6
5
μ
A
TEST
MIN
TYP
MAX
UNIT
PARAMETER
CONDITIONS
t
loop1
t
loop2
Total loop delay, driver input to receiver output, Recessive to Dominant
Total loop delay, driver input to receiver output, Dominant to Recessive
90
90
230
230
STB at 0 V,
See
Figure 9
ns
3
Submit Documentation Feedback