UHE Series
Isolated, High Efciency, 1.6" × 2"
2-10 Amp, 12-30 Watt DC/DC Converters
MDC_UHE_12-30W Series.B18 Page 5 of 16
www.murata-ps.com
Output
Overvoltage Protection:
Magnetic feedback
1.2V Outputs
1.5-2.1 Volts
1.5V Outputs
1.8-2.4 Volts
1.8V Outputs
2.2-2.8 Volts
2.5V Outputs
2.8 to 3.2 Volts
3.3V Outputs
4 to 4.8 Volts
5V Outputs
6.1-7.5 Volts
12V Outputs
12.7-13.5 Volts
15V Outputs
15.8-16.2 Volts
Maximum Capacitive Loading:
10,000μF (1.2-5VOUT)
(Low ESR capacitor)
2,000μF (12-15VOUT)
Dynamic Characteristics
Dynamic Load Response:
(50-100% load step to ±3% VOUT)
200μsec maximum
Start-Up Time:
8msec typical
VIN to VOUT and On/Off to VOUT
15msec maximum
UHE-15/2000-Q12
30mS typ., 50mS max.
Switching Frequency
150-350kHz (model dependent)
Environmental
MTBF
TBC million hours
Operating Temperature (Ambient):
–40 to +85°C with Derating
(see Derating Curves)
Thermal Shutdown
+115°C to +130°C
Storage Temperature
–55 to +125°C
Flammability
UL 94 V-0
Physical
Dimensions
1.6" x 2" x 0.40" (40.64 x 50.8 x 10.16mm)
Case Material
Diallyl Phthalate
Pin Material
Gold-plated copper alloy
Weight
1.51 ounces (46.9 grams)
Primary to Secondary Insulation Level
Basic
Performance/Functional Specications
Typical @ TA = +25°C under nominal line voltage and full-load conditions, unless noted.
Input
Input Voltage Range:
D12 Models (start up at 10V max.)
9-18 Volts (12V nominal)
Q12 Models (start up at 10V max.)
9-36 Volts (24V nominal)
D24 Models
18-36 Volts (24V nominal)
Q48 Models
18-75 Volts (48V nominal)
D48 Models
36-75 Volts (48V nominal)
Overvoltage Shutdown:
D12 Models
18.5-23 Volts
Q12/D24 Models
37-42 Volts
D48/Q48 Models
Not applicable
Start-Up Threshold:
D12/Q12 Models
9.4-10 Volts
D24/Q48 Models
15.5-18 Volts
D48 Models
33.5-36 Volts
Undervoltage Shutdown:
D12/Q12 Models
7.0-8.8 Volts
D24/Q48 Models
15-17 Volts
D48 Models
32-35.5 Volts
Input Current:
Normal Operating Conditions
See Ordering Guide
Standby Mode (Off, OV, UV)
5mA
Input Reected Ripple Current
2.5-10mAp-p
Input Filter Type
LC or Pi type
Reverse-Polarity Protection
Brief duration, 5A maximum
Remote On/Off Control (Pin 4):
Positive Logic (Standard)
On = open, open collector, or to +15V
applied. IIN = 2.6mA max.
Off = pulled low to 0-0.8V. IIN = 2mA max.
Negative Logic ("N" Sufx Models)
On = pulled low to 0-0.8V. IIN = 6mA max.
Off = open, open collector or to +15V
applied. IIN = 1mA max.
Output
VOUT Accuracy (50% load):
Initial
±1.5%
Temperatue Coefcient
±0.02% per °C
Extreme(5)
±3%
Minimum Loading for Specication:
No load
Ripple/Noise (20MHz BW)
See Ordering Guide
Line/Load Regulation
See Ordering Guide
Efciency
See Ordering Guide
VOUT Trim Range(6)
±5% minimum (±10% for T models)
Remote Sense Compensation
±5%
Isolation Voltage:
Input-to-Output
1500Vdc minimum (BASIC)
Isolation Capacitance
650pF
Isolation Resistance
100M
:
Current Limit Inception (@98%VOUT):
10 Amp Models
12-15 Amps
7.5 Amp Models
8.2-11.5 Amps
5/6 Amp Models
6.5-8.5 Amps
2.5 Amp Models
2.6-4 Amps
2.0 Amp Models
2.1-3 Amps
Short Circuit Current (Hiccup)
1.5-2.3 Amps
All models are tested and specied with a single, external, 0.47μF, multi-layer ceramic output
capacitor and no external input capacitors, unless otherwise noted. All models will effectively
regulate under no-load conditions (with perhaps a slight increase in output ripple/noise).
See Technical Notes/Performance Curves for additional explanations and details.
Input Ripple Current is tested/specied over a 5-20MHz bandwidth with an external 33μF input
capacitor and a simulated source impedance of 220μF and 12μH. See I/O Filtering, Input Ripple
Current and Output Noise for details.
The On/Off Control is designed to be driven with open-collector (or equivalent) logic or the applica-
tion of appropriate voltages (referenced to –Input (pin 2)). Applying a voltage to the On/Off Control
pin when no input voltage is applied to the converter can cause permanent damage. See Remote
On/Off Control for more details.
Extreme Accuracy refers to the accuracy of either trimmed or untrimmed output voltages over all
normal operating ranges and combinations of input voltage, output load and temperature.
Tie the Output Trim pin (pin 9) to +Output (pin 6) for maximum trim down or to –Output (Output
Return/Common, pin 7) for maximum trim up. See Output Trimming for detailed trim equations.
The Current-Limit-Inception point is the output current level at which the converter's power-limiting
circuitry drops the output voltage 2% from its initial value. See Output Current Limiting and
Short-Circuit Protection for more details.
For Start-Up-Time specications, output settling time is dened as the output voltage having
reached ±1% of its nal value at maximum load current.
MTBF’s are calculated using TELCORDIA SR-332 Method 1 Case, ground xed, +25°C ambient air
and full-load conditions. Contact MPS for demonstrated life-test data.
All models are fully operational and meet all published specications, including "cold start," at –40°C.
Use only as much output ltering as needed and no more. Larger caps (especially low-ESR ceramic
types) may slow transient response or degrade dynamic performance. Thoroughly test your system
with all components installed.