absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage range, V
CC
(see Note 1)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous power dissipation at (or below) T
A
= 25
°
C
Operating free-air temperature range, T
A
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, T
STG
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds
–0.4 V to 7 V
892 mW
–20
°
C to 45
°
C
–65
°
C to 150
°
C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
260
°
C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: This voltage value is with respect to the GND.
recommended operating conditions
MIN
NOM
MAX
UNIT
Supply voltage, VCC
Reference voltage, VREF
High-level input voltage, VIH
Low-level input voltage, VIL
High-level output current, IOH
Low-level output current, IOL
4.75
5
5.25
V
1.93
2
2.7
V
S/HP, S/HD1, S/HD2
4.5
V
S/HP, S/HD1, S/HD2
0.5
V
μ
A
μ
A
HIB
10
LOB
10
Iris amplifier
S/HFB to IRIS
5
AGC amplifier
IRIS to AGCOUT
8
Bandwidth
Gamma amplifier
AMPIN to AMPOUT
8
MHz
Aperture amplifier
YIN to APOUT
8
Output amplifier
YHIN to VIDEO
8
Clock frequency, fclock
Pulse duration, tw
Operating free-air temperature, TA
S/HP, S/HD1, S/HD2
15
MHz
S/HP, S/HD1, S/HD2
11
ns
°
C
–20
45
all sections
PARAMETER
TEST CONDITIONS
MIN
MAX
UNIT
Supply current, ICC
VCC = 5.25 V
20
41
mA
sample-and-hold section
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
Input voltage, VI
DATAIN
HOBP = 5 V
2.5
2.6
2.7
V
Input current, II
DATAIN
VCC = 5.25 V,
HOBP = 0 V
VI = 2.5 V,
–0.2
0.05
0.2
μ
A
High-level input current, IIH
S/HP, S/HD1, S/HD2
VCC = 5.25 V,
VI = 5 V
–1
1
μ
A
Low level input current IIL
Low-level input current, IIL
S/HP
VCC= 5 25 V
VCC = 5.25 V,
VI= 0 V
VI = 0 V
–90
μ
A
S/HD1, S/HD2
–200
Input voltage, VI
S/HFB
HOBP = 5 V
2.7
V
Gain, GP
DATAIN to IRIS
S/HP, S/HD1, S/HD2, and
WINDOW = 5 V
1
Input signal voltage, VI(PP)
Clamp output impedance, IOZ
Input current, II
DATAIN
0.5
V
k
nA
DATAIN
3.5
5
6.5
S/HFB
–200
200