SN54LVU04, SN74LVU04
HEX INVERTERS
SCLS185B – FEBRUARY 1993 – REVISED APRIL 1996
3
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
SN54LVU04
MIN
VCC–0.5
2.4
SN74LVU04
MIN
VCC–0.5
2.4
UNIT
VCC
TYP
MAX
TYP
MAX
VI = VIL,
VI = GND,
VI = GND,
VI = VIH,
VI = VCC,
VI = VCC,
IOH = –100
μ
A
IOH = – 6 mA
IOH = – 12 mA
IOL = 100
μ
A
IOL = 6 mA
IOL = 12 mA
MIN to MAX
VOH
3 V
V
4.5 V
3.6
3.6
MIN to MAX
0.5
0.5
VOL
3 V
0.4
0.4
V
4.5 V
0.55
±
1
±
1
20
0.55
±
1
±
1
20
II
VI= VCCor GND
VI = VCC or GND
3.6 V
μ
A
5.5 V
ICC
VI= VCCor GND
VI = VCC or GND,
IO= 0
IO = 0
3.6 V
μ
A
5.5 V
20
20
ICC
One input at VCC – 0.6 V,
Other inputs at VCC or GND
3 V to 3.6 V
500
500
μ
A
Ci
VI= VCCor GND
VI = VCC or GND
3.3 V
7
7
pF
5 V
7.5
7.5
For conditions shown as MIN or MAX, use the appropriate values under recommended operating conditions.
switching characteristics over recommended operating free-air temperature range, C
L
= 50 pF
(unless otherwise noted) (see Figure 1)
FROM
(INPUT)
TO
SN54LVU04
VCC = 3.3 V
±
0.3 V
MIN
TYP
PARAMETER
(OUTPUT)
VCC = 5 V
±
0.5 V
MIN
TYP
VCC = 2.7 V
MIN
UNIT
MAX
MAX
MAX
tpd
A
Y
5
10
8
13
13
ns
switching characteristics over recommended operating free-air temperature range, C
L
= 50 pF
(unless otherwise noted) (see Figure 1)
FROM
(INPUT)
TO
SN74LVU04
VCC = 3.3 V
±
0.3 V
MIN
TYP
PARAMETER
(OUTPUT)
VCC = 5 V
±
0.5 V
MIN
TYP
VCC = 2.7 V
MIN
UNIT
MAX
MAX
MAX
tpd
A
Y
5
10
8
13
13
ns
operating characteristics, T
A
= 25
°
C
PARAMETER
TEST CONDITIONS
VCC
3.3 V
TYP
7
UNIT
Cpd
Power dissipation capacitance per inverter
Power dissi ation ca acitance er inverter
CL= 50 pF
CL = 50 F,
f = 10 MHz
pF
5 V
12
PRODUCT PREVIEW information concerns products in the formative or
design phase of development. Characteristic data and other
specifications are design goals. Texas Instruments reserves the right to
change or discontinue these products without notice.