SN75976A, SN55976A
9-CHANNEL DIFFERENTIAL TRANSCEIVER
SLLS218B – MAY 1995 – REVISED MAY 1997
6
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage range, V
CC
(see Note 1)
Bus voltage range
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Data I/O and control (A side) voltage range
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electrostatic discharge:B side and GND, Class 3, A: (see Note 2)
B side and GND, Class 3, B: (see Note 2)
All terminals, Class 3, A:
All terminals, Class 3, B:
Continuous total power dissipation (see Note 3)
Storage temperature range, T
stg
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds
–0.3 V to 6 V
–10 V to 15 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
–0.3 V to V
CC
+0.5 V
12 kV
400 V
4 kV
400 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
internally limited
–65
°
C to 150
°
C
260
°
C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES:
1. All voltage values are with respect to the GND terminals.
2. This absolute maximum rating is tested in accordance with MIL-PRF-38535, Method 3015.7.
3. The maximum operating junction temperature is internally limited. Use the Dissipation Rating Table to operate below this
temperature.
DISSIPATION RATING TABLE
OPERATING FACTOR
ABOVE TA = 25
°
C
20 mW/
°
C
20 mW/
°
C
PACKAGE
TA
≤
25
°
C
TA = 70
°
C
POWER RATING
TA = 125
°
C
POWER RATING
DGG
2500 mW
1600 mW
—
DL
2500 mW
1600 mW
—
WD
1300 mW
10.5 mW/
°
C
827 mW
250 mW
This is the inverse of the junction-to-ambient thermal resistance when board-mounted and with no air flow.
package thermal characteristics
MIN
NOM
MAX
UNIT
°
C/W
°
C/W
°
C/W
°
C/W
°
C/W
°
C/W
°
C
Junction to ambient thermal resistance R
Junction-to-ambient thermal resistance, R
θ
JA
DGG, board-mounted, no air flow
50
DL, board-mounted, no air flow
50
Junction-to-ambient thermal resistance, R
θ
JA
WD
95.4
Junction to case thermal resistance R
Junction-to-case thermal resistance, R
θ
JC
DGG
27
DL
12
Junction-to-case thermal resistance, R
θ
JC
Thermal-shutdown junction temperature, TJS
WD
5.67
165