absolute maximum ratings over operating free-air temperature range
Supply voltage range, V
CC
Input clamp current, I
IK
(V
I
< 0 or V
I
> V
CC
) (see Note 1)
Output clamp current, I
OK
(V
O
< 0 or V
O
> V
CC
) (see Note 1)
Continuous output current, I
O
(V
O
= 0 to V
CC
)
Continuous current through V
CC
or GND
Maximum power dissipation at T
A
= 55
°
C (in still air) (see Note 2): D package
–0.5 V to 7 V
±
20 mA
±
20 mA
±
25 mA
±
50 mA
1.25 W
. . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
DB and PW packages
N package
0.5 W
1.1 W
. . . . . . . . . . . . . . . . . . . .
Storage temperature range, T
stg
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES:
1. The input and output voltage ratings may be exceeded if the input and output current ratings are observed.
2. The maximum package power dissipation is calculated using a junction temperature of 150
°
C and a board trace length of 750 mils,
except for the N package, which has a trace length of zero.
–65
°
C to 150
°
C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
recommended operating conditions
SN54HCT32
MIN
NOM
SN74HCT32
MIN
NOM
UNIT
MAX
MAX
VCC
VIH
VIL
VI
VO
tt
TA
Supply voltage
4.5
5
5.5
4.5
5
5.5
V
High-level input voltage
VCC = 4.5 V to 5.5 V
VCC = 4.5 V to 5.5 V
2
2
V
Low-level input voltage
0
0.8
0
0.8
V
Input voltage
0
VCC
VCC
500
0
VCC
VCC
500
V
Output voltage
0
0
V
Input transition (rise and fall) time
0
0
ns
°
C
Operating free-air temperature
–55
125
–40
85
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
VCC
TA = 25
°
C
TYP
4.499
SN54HCT32
SN74HCT32
UNIT
MIN
4.4
MAX
MIN
4.4
MAX
MIN
4.4
MAX
VOH
VI= VIHor VIL
VI = VIH or VIL
IOH = –20
μ
A
IOH = –4 mA
IOL = 20
μ
A
IOL = 4 mA
4 5 V
4.5 V
V
3.98
4.3
3.7
3.84
VOL
VI= VIHor VIL
VI = VIH or VIL
4 5 V
4.5 V
0.001
0.1
0.1
0.1
V
0.17
±
0.1
0.26
±
100
0.4
0.33
±
1000
II
ICC
VI = VCC or 0
VI = VCC or 0,
One input at 0.5 V or 2.4 V,
Other inputs at 0 or VCC
5.5 V
±
1000
nA
μ
A
IO = 0
5.5 V
2
40
20
ICC
5.5 V
1.4
2.4
3
2.9
mA
Ci
4.5 V
to 5.5 V
3
10
10
10
pF
This is the increase in supply current for each input that is at one of the specified TTL voltage levels rather than 0 or VCC.
PRODUCT PREVIEW information concerns products in the formative or
design phase of development. Characteristic data and other
specifications are design goals. Texas Instruments reserves the right to
change or discontinue these products without notice.