DMA
S3C2440A RISC MICROPROCESSOR
8-14
DMA MASK TRIGGER (DMASKTRIG) REGISTER
Register
Address
R/W
Description
Reset Value
DMASKTRIG0
0x4B000020
R/W
DMA 0 mask trigger register
000
DMASKTRIG1
0x4B000060
R/W
DMA 1 mask trigger register
000
DMASKTRIG2
0x4B0000A0
R/W
DMA 2 mask trigger register
000
DMASKTRIG3
0x4B0000E0
R/W
DMA 3 mask trigger register
000
DMASKTRIGn
Bit
Description
Initial State
STOP
[2]
Stop the DMA operation.
1: DMA stops as soon as the current atomic transfer ends. If there
is no current running atomic transfer, DMA stops immediately. The
CURR_TC, CURR_SRC, and CURR_DST will be 0.
Note:
Due to possible current atomic transfer, “stop” operation may
take
several cycles. The finish of the operation (i.e. actual stop time)
can be detected as soon as the channel on/off bit
(DMASKTRIGn[1]) is set to off. This stop is “actual stop”.
0
ON_OFF
[1]
DMA channel on/off bit.
0: DMA channel is turned off.
(DMA request to this channel is ignored.)
1: DMA channel is turned on and the DMA request is handled. This
bit is automatically set to off if we set the DCONn[22] bit to “no
auto reload” and/or STOP bit of DMASKTRIGn to “stop”.
Note that when DCON[22] bit is "no auto reload", this bit becomes
0 when CURR_TC reaches 0. If the STOP bit is 1, this bit becomes
0 as soon as the current atomic transfer is completed.
Note:
This bit should not be changed manually during DMA operations
(i.e. this has to be changed only by using DCON[22] or STOP bit).
0
SW_TRIG
[0]
Trigger the DMA channel in S/W request mode.
1: it requests a DMA operation to this controller.
Note that this trigger gets effective after S/W request mode has to
be selected (DCONn[23]) and channel ON_OFF bit has to be set to
1 (channel on). When DMA operation starts, this bit is cleared
automatically.
0
NOTE:
You are allowed to change the values of DISRC register, DIDST registers, and TC field of DCON register. Those
changes take effect only after the finish of current transfer (i.e. when CURR_TC becomes 0). On the other hand, any
change made to other registers and/or fields takes immediate effect. Therefore, be careful in changing those
registers and fields.