DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature (unless otherwise noted)
Supply voltage, V
DD
(see Note1)
Output voltage V
O
: FPO
16 V
16 V
8 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous total power dissipation
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating free-air temperature range, T
A
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, T
stg
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Soldering temperature
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PGO
All other pins (see Note 1)
–
0.3 V to 16 V
See Dissipation Rating Table
–
40
°
C to 85
°
C
–
65
°
C to 150
°
C
260
°
C
Stresses beyond those listed under
“
absolute maximum ratings
”
may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under
“
recommended operating conditions
”
is not
implied. Exposure to absolute
–
maximum
–
rated conditions for extended periods may affect device reliability.
NOTE 1: All voltage values are with respect to GND.
DISSIPATION RATING TABLE
PACKAGE
TA
≤
25
°
C
POWER RATING
DERATING FACTOR
ABOVE TA = 25
°
C
8.74 mW/
°
C
5.84 mW/
°
C
TA = 70
°
C
POWER RATING
TA = 85
°
C
POWER RATING
P
1092 mW
699 mW
568 mW
D
730 mW
467 mW
379 mW
recommended operating conditions at specified temperature range
MIN
NOM
MAX
UNIT
Supply voltage, VDD
4
15
V
PSON, VS5, VS33
7
Input voltage, VI
PGI
VDD + 0.3 V
(max = 7 V)
V
Output voltage V
Output voltage, VO
FPO
15
V
PGO
7
O tp t sink c rrent I
Output sink current, IO,sink
FPO
20
mA
PGO
10
Supply voltage rising time, tr
Operating free-air temperature range, TA
NOTE 2: VDD rising and falling slew rate must be less than 14 V/ms.
See Note 2
1
ms
°
C
–
40
85