2
EN/LZT 146 089 R1A Ericsson Power Modules AB, March 2005
Characteristics
Conditions
min
typ
max
Unit
VI
Input voltage range1)2)
36
75
V
VIoff
Turn-off input voltage
See typical characteristics
30.0
33.5
35.0
V
VIon
Turn-on input voltage
See typical characteristics
32.0
34.5
36.0
V
CI
Input capacitance
2
F
PIi
Input idling power
IO= 0, TC=–30…+95°C
(VI=53V)
720
mW
PRC
Input stand-by power
TC=–30…+95°C,
RC connected to pin 17
(VI=53V)
40
mW
Characteristics
min
max
Unit
TC
Case temperature at full output power
-45
+100
°C
TS
Storage temperature
-55
+125
°C
VI
Continuous input voltage1)
-0.5
+85
Vdc
VISO
Isolation voltage
(input to output test voltage)
1,500
Vdc
Etr
Transient input energy
0.1
Ws
VRC
Remote control voltage pin 10,11 ref. to pin 17
-5
+16
Vdc
Vadj
Output adjust voltage pin 8,9 ref. to pin 17
-5
+40
Vdc
1)
The input voltage range 36…75 V dc meets
the European Telecom Standard prETS
300 132-2 Nominal input voltage range
in 48 V and 60 V dc power systems,
–40.5…–57.0 V and –50.0… – 72.0 V respec-
tively. Absolute max continuous input voltage
is 80 Vdc.
2)
The power module will operate down to
≤ 35V, when VI decreases, but will turn on to at
VI
≤ 36V, when VI increases
(see also Operating information).
Stress in excess of Absolute Maximum
Ratings may cause permanent damage.
Absolute Maximum Ratings, sometimes
referred to as no destruction limits, are
normally tested with one parameter at a
time exceeding the limits of Output data or
Electrical Characteristics. If exposed to stress
above these limits, function and performance
may degrade in an unspecied manner.
Absolute Maximum Ratings
Input TC < TCmax unless otherwise specied
Notes:
Connections
18 17 16 15 14 13 12 11 10
1
2
3
4
5
6
7
8
9
Note: Galvanic isolation is veried in an electric strenght test. Test voltage is 1.500 Vdc for 60s. In
production the test duration may be decreased to 1 s.
Pin
Designation
Function
1
Out 1
Output 1(+).
2
Rtn
Output return.
3-6
NC
Not connected. Galvanically Isolated from input pins.
7
RC
Remote control.
8Vadj
Output voltage adjust.
9
NOR
Connection of Nominal Output voltage Resistor.
10
+In
Positive Input.
11
–In
Negative input.
12–16
NC
Not connected. Galvanically isolated from input pins.
17
Rtn
Output return.
18
Out 2
Output 2(+).
For detailed mechanical information see PKF
general datasheet
Top view