MCP9808
DS25095A-page 18
?2011 Microchip Technology Inc.
5.1.1
SENSOR CONFIGURATION
REGISTER (CONFIG)
The MCP9808 has a 16-bit Configuration register
(CONFIG) that allows the user to set various functions for
a robust temperature monitoring system. Bits 10 through
0 are used to select the temperature alert output
hysteresis,   device   shutdown   or   Low-Power   mode,
temperature boundary and critical temperature lock, and
temperature Alert output enable/disable. In addition, Alert
output condition (output set for T
UPPER
and T
LOWER
temperature boundary or T
CRIT
only), Alert output status
and Alert output polarity and mode (Comparator Output
or Interrupt Output mode) are user-configurable.
The temperature hysteresis bits 10 and 9 can be used
to    prevent   output    chatter   when    the   ambient
temperature     gradually     changes     beyond     the
user-specified
temperature
boundary
(see
Section 5.2.2 Temperature Hysteresis (T
HYST
).
The Continuous Conversion or Shutdown mode is
selected using bit 8. In Shutdown mode, the band gap
temperature     sensor     circuit     stops     converting
temperature and the Ambient Temperature register
(T
A
)   holds   the   previous   temperature   data   (see
Section 5.2.1 Shutdown Mode). Bits 7 and 6 are
used to lock the user-specified boundaries T
UPPER
,
T
LOWER
and T
CRIT
to prevent an accidental rewrite.
The Lock bits are cleared by resetting the power. Bits 5
through 0 are used to configure the temperature Alert
output pin. All functions are described in Register 5-2
(see Section 5..3 Alert Output Configuration).
REGISTER 5-2:
CONFIG: CONFIGURATION REGISTER (?/SPAN> ADDRESS 0000 0001b)
U-0
U-0
U-0
U-0
U-0
R/W-0
R/W-0
R/W-0
T
HYST
SHDN
bit 15
bit 8
R/W-0
R/W-0
R/W-0
R-0
R/W-0
R/W-0
R/W-0
R/W-0
Crit. Lock
Win. Lock
Int. Clear
Alert Stat.
Alert Cnt.
Alert Sel.
Alert Pol.
Alert Mod.
bit 7
bit 0
Legend:
R = Readable bit
W = Writable bit
U = Unimplemented bit, read as 0
-n = Value at POR
1 = Bit is set
0 = Bit is cleared
x = Bit is unknown
bit 15-11
Unimplemented: Read as 0
bit 10-9
T
HYST
: T
UPPER
and T
LOWER
Limit Hysteresis bits
00 =  0癈 (power-up default)
01 =  +1.5癈
10 =  +3.0癈
11 =  +6.0癈
(Refer to Section 5.2.3 Alert Output Configuration.)
This bit can not be altered when either of the Lock bits are set (bit 6 and bit 7).
This bit can be programmed in Shutdown mode.
bit 8
SHDN: Shutdown Mode bit
0 =  Continuous conversion (power-up default)
1 =  Shutdown (Low-Power mode)
In shutdown, all power-consuming activities are disabled, though all registers can be written to or read.
This bit cannot be set to 1 when either of the Lock bits is set (bit 6 and bit 7). However, it can be
cleared to 0 for continuous conversion while locked (refer to Section 5.2.1 Shutdown Mode).