MCH12140, MCK12140
http://onsemi.com
3
Table 4. MAXIMUM RATINGS
Symbol
Rating
Value
Unit
VEE
Power Supply (VCC = 0 V)
8.0 to 0
VDC
VI
Input Voltage (VCC = 0 V)
0 to 6.0
VDC
Iout
Output Current
Continuous
Surge
50
100
mA
TA
Operating Temperature Range
40 to +70
°C
VEE
Operating Range (Note 3)
5.7 to 4.2
V
Stresses exceeding Maximum Ratings may damage the device. Maximum Ratings are stress ratings only. Functional operation above the
Recommended Operating Conditions is not implied. Extended exposure to stresses above the Recommended Operating Conditions may affect
device reliability.
NOTE: ESD data available upon request.
1. 10H circuits are designed to meet the DC specifications shown in the table after thermal equilibrium has been established. The circuit is in
a test socket or mounted on a printed circuit board and transverse airflow greater than 500 lfpm is maintained. Outputs are terminated through
a 50 W resistor to 2.0 V except where otherwise specified on the individual data sheets.
2. This table replaces the three tables traditionally seen in ECL 100 K data books. The same DC parameter values at VEE = 4.5 V now apply
across the full VEE range of 4.2 V to 5.5 V. Outputs are terminated through a 50 W resistor to 2.0 V except where otherwise specified
on the individual data sheets.
3. Parametric values specified at:
HSeries: 4.20 V to 5.50 V
KSeries: 4.94 V to 5.50 V
Table 5. DC CHARACTERISTICS (VEE = VEE(min) VEE(max); VCC = GND, unless otherwise noted.)
Symbol
Characteristic
40°C
0°C
25°C
70°C
Unit
Min
Typ
Max
Min
Typ
Max
Min
Typ
Max
Min
Typ
Max
IEE
Power Supply Current H
K
45
38
45
52
38
45
52
38
42
45
50
52
58
mA
VEE
Power Supply Voltage H
K
4.75
4.20
5.2
4.5
5.5
4.75
4.20
5.2
4.5
5.5
4.75
4.20
5.2
4.5
5.5
4.75
4.20
5.2
4.5
5.5
V
IIH
Input HIGH Current
150
150
150
150
mA
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
Table 6. AC CHARACTERISTICS (VEE = VEE(min) VEE(max); VCC = GND, unless otherwise noted.)
Symbol
Characteristic
40°C
0°C
25°C
70°C
Unit
Min
Typ
Max
Min
Typ
Max
Min
Typ
Max
Min
Typ
Max
FMAX
Maximum Toggle Frequency
800
650
800
650
800
650
800
tPLH
tPHL
Propagation DelaytoOutput
R, V to D, U 250
375
500
250
375
500
250
375
500
250
375
500
ps
tr
tf
Output Rise/Fall Times
Q (20 to 80%)
225
100
225
350
100
225
350
100
225
350
ps
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.