MCH12140 MCK12140
2
MOTOROLA RF/IF DEVICE DATA
TRUTH TABLE*
Input
Output
Input
Output
R
V
U
D
U
D
R
V
U
D
U
D
0
0
1
0
0
1
1
1
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
1
1
1
1
1
0
1
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
0
0
1
0
1
1
1
1
1
0
1
1
1
1
0
0
0
0
0
0
0
0
1
1
1
1
1
0
1
1
1
1
0
0
0
1
1
0
1
1
1
0
0
1
NOTE:
the device will function properly.
H–SERIES DC CHARACTERISTICS
(VEE = VEE(min) – VEE(max); VCC = GND
1
, unless otherwise noted.)
* This is not strictly a functional table; i.e., it does not cover all possible modes of operation. However, it gives a sufficient number of tests to ensure that
–40
°
C
0
°
C
25
°
C
70
°
C
Characteristic
Symbol
Min
Max
Min
Max
Min
Max
Min
Max
Unit
Output HIGH Voltage
VOH
–1080
–890
–1020
–840
–980
–810
–910
–720
mV
Output LOW Voltage
VOL
–1950
–1650
–1950
–1630
–1950
–1630
–1950
–1595
mV
Input HIGH Voltage
VIH
–1230
–890
–1170
–840
–1130
–810
–1060
–720
mV
Input LOW Voltge
VIL
–1950
–1500
–1950
–1480
–1950
–1480
–1950
–1445
mV
Input LOW Current
IIL
0.5
—
0.5
—
0.5
—
0.3
—
μ
A
NOTE:
1.10H circuits are designed to meet the DC specifications shown in the table after thermal equilibrium has been established. The circuit is in a test socket
or mounted on a printed circuit board and transverse airflow greater than 500lfpm is maintained. Outputs are terminated through a 50
resistor to –2.0V
except where otherwise specified on the individual data sheets.
K–SERIES DC CHARACTERISTICS
(VEE = VEE(min) – VEE(max); VCC = GND
1
, unless otherwise noted.)
–40
°
C
0
°
C to 70
°
C
Characteristic
Symbol
Min
Typ
Max
Min
Typ
Max
Unit
Condition
Output HIGH Voltage
VOH
–1085
–1005
–880
–1025
–955
–880
mV
VIN = VIH(max)
Output LOW Voltage
VOL
–1830
–1695
–1555
–1810
–1705
–1620
mV
or VIL(min)
Output HIGH Voltage
VOHA
–1095
—
—
–1035
—
—
mV
VIN = VIH(min)
Output LOW Voltage
VOLA
—
—
–1555
—
—
–1610
mV
or VIL(max)
Input HIGH Voltage
VIH
–1165
—
–880
–1165
—
–880
mV
Input LOW Voltge
VIL
–1810
—
–1475
–1810
—
–1475
mV
Input LOW Current
IIL
0.5
—
—
0.5
—
—
μ
A
VIN = VIL(max)
NOTE:
1.This table replaces the three tables traditionally seen in ECL 100K data books. The same DC parameter values at VEE = –4.5V now apply across the
full VEE range of –4.2V to –5.5V. Outputs are terminated through a 50
resistor to –2.0V except where otherwise specified on the individual data
sheets.
ABSOLUTE MAXIMUM RATINGS
(Note 1)
Characteristic
Symbol
Rating
Unit
Power Supply (VCC = 0V)
VEE
–8.0 to 0
VDC
Input Voltage (VCC = 0V)
VI
0 to –6.0
VDC
Output Current
Continuous
Surge
Iout
50
100
mA
Operating Temperature Range
TA
–40 to +70
°
C
Operating Range
1,2
VEE
–5.7 to –4.2
V
NOTES:
1.Absolute maximum rating, beyond which, device life may be impaired, unless otherwise specified on an individual data sheet.
2.Parametric values specified at:
H–Series: –4.20 V to –5.50 V
K–Series: –4.94 V to –5.50 V
3.ESD data available upon request.