![](http://datasheet.mmic.net.cn/330000/MB90F583B_datasheet_16438001/MB90F583B_20.png)
MB90580B Series
20
It is recommended to provide a bypass capacitor of around 0.1
μ
F between V
CC
and V
SS
pin near the device.
6.
Crystal Oscillator Circuit
Noises around X0 or X1 pins may be possible causes of abnormal operations. Make sure to provide bypass
capacitors via shortest distance from X0, X1 pins, crystal oscillator (or ceramic resonator) and ground lines, and
make sure, to the utmost effort, that lines of oscillation circuit not cross the lines of other circuits.
It is highly recommended to provide a printed circuit board art work surrounding X0 and X1 pins with an grand
area for stabilizing the operation.
Turning-on Sequence of Power Supply to A/D Converter and Analog Inputs
7.
Make sure to turn on the A/D converter power supply (AV
CC
, AV
SS
, AVRH, AVRL) and analog inputs (AN0 to AN7)
after turning-on the digital power supply (V
CC
).
Turn-off the digital power after turning off the A/D converter supply and analog inputs. In this case, make sure
that the voltage of AVRH dose not exceed AV
CC
(turning on/off the analog and digital power supplies simulta-
neously is acceptable).
Connection of Unused Pins of A/D Converter
8.
Connect unused pin of A/D converter to AV
CC
= V
CC
, AV
SS
= AVRH = AVRL = V
SS
.
Connection of Unused Pins of D/A Converter
9.
Connect unused pin of D/A converter to DVRH = V
SS
, DV
SS
= V
SS
.
10. N.C. Pin
The N.C. (internally connected) pin must be opened for use.
11. Notes on Energization
To prevent the internal regulator circuit from malfunctioning,set the voltage rise time during energization at
50
μ
s or more (0.2 V to 2.7 V).
V
CC
V
SS
V
CC
V
CC
V
CC
V
CC
V
SS
V
SS
V
SS
V
SS
MB90580B
Series