Rev.3.00
2004.08.06
page 102 of 155
REJ03B0010-0300Z
4584 Group
PRELIMINARY
Notice: This is not a final specification.
Some parametric limits are subject to change.
SNZP (Skip if Non Zero condition of Power down flag)
0000000011
003
11
–
(P) = 1
Grouping:
Other operation
Description: Skips the next instruction when the P flag is
“1”.
After skipping, the P flag remains un-
changed.
Executes the next instruction when the P
flag is “0.”
Operation:
(P) = 1 ?
SNZAD (Skip if Non Zero condition of A/D conversion completion flag)
1010000111
287
11
–
V22 = 0: (ADF) = 1
Grouping:
A/D conversion operation
Description: When V22 = 0 : Skips the next instruction
when A/D conversion completion flag ADF
is “1.” After skipping, clears (0) to the ADF
flag. When the ADF flag is “0,” executes the
next instruction.
When V22 = 1 : This instruction is equiva-
lent to the NOP instruction.
Operation:
V22 = 0: (ADF) = 1 ?
After skipping, (ADF)
← 0
V22 = 1: SNZAD = NOP
(V22 : bit 2 of the interrupt control register V2)
SNZI0 (Skip if Non Zero condition of external 0 Interrupt input pin)
0000111010
03A
11
–
I12 = 0 : (INT0) = “L”
I12 = 1 : (INT0) = “H”
Grouping:
Interrupt operation
Description: When I12 = 0 : Skips the next instruction
when the level of INT0 pin is “L.” Executes
the next instruction when the level of INT0
pin is “H.”
When I12 = 1 : Skips the next instruction
when the level of INT0 pin is “H.” Executes
the next instruction when the level of INT0
pin is “L.”
Operation:
I12 = 0 : (INT0) = “L” ?
I12 = 1 : (INT0) = “H” ?
(I12 : bit 2 of the interrupt control register I1)
SNZI1 (Skip if Non Zero condition of external 1 Interrupt input pin)
0000111011
03B
11
–
I22 = 0 : (INT1) = “L”
I22 = 1 : (INT1) = “H”
Grouping:
Interrupt operation
Description: When I22 = 0 : Skips the next instruction
when the level of INT1 pin is “L.” Executes
the next instruction when the level of INT1
pin is “H.”
When I22 = 1 : Skips the next instruction
when the level of INT1 pin is “H.” Executes
the next instruction when the level of INT1
pin is “L.”
Operation:
I22 = 0 : (INT1) = “L” ?
I22 = 1 : (INT1) = “H” ?
(I22 : bit 2 of the interrupt control register I2)
MACHINE INSTRUCTIONS (INDEX BY ALPHABET) (continued)