Timer X
Mitsubishi microcomputers
M30201 Group
SINGLE-CHIP 16-BIT CMOS MICROCOMPUTER
234
2.4.7 Operation of Timer X (one-shot timer mode)
Figure 2.4.14. Operation timing of one-shot mode
In one-shot timer mode, choose functions from those listed in Table 2.4.6. Operations of the circled items
are described below. Figure 2.4.14 shows the operation timing, and Figure 2.4.15 shows the set-up
procedure.
Operation (1) Setting the one-shot start flag to “1” with the count start flag set to “1” causes the counter to
perform a down count on the count source. At this time, the TXiINOUT pin outputs an “H” level.
(2) The instant the value of the counter becomes “000016”, the TXiINOUT pin outputs an “L” level,
and the counter reloads the content of the reload register and stops counting. At this time, the
timer Xi interrupt request bit goes to “1”.
(3) If a trigger occurs while a count is in progress, the counter reloads the value in the reload
register again and continues counting. The reload timing is in step with the next count source
input after the trigger.
(4) Setting the count start flag to “0” causes the counter to stop and to reload the content of the
reload register. Also, the TXiINOUT pin outputs an “L” level. At this time, the timer Xi interrupt
request bit goes to “1”.
Table 2.4.6. Choosed functions
Item
Count source
Pulse output function
Count start condition
Set-up
O
Internal count source (f1 / f8 / f32 / fc32)
No pulses output
Pulses output
External trigger input (falling edge of input signal to the TXiINOUT pin)
External trigger input (rising edge of input signal to the TXiINOUT pin)
Timer overflow (TB1/TX0/TXi overflow)
Writing “1” to the one-shot start flag
FFFF16
n
000116
Timer Xi interrupt
request bit
Counter
content
(hex)
n = reload register content
Reload
One-shot pulse output
from TXiINOUT pin
“H”
1 / fi X (n)
“L”
Time
Reload
1 / fi X (n+1)
Write signal to
one-shot start flag
“1”
“0”
Count start flag
“1”
“0”
(1) Start count
Cleared to “0” when interrupt request is accepted, or cleared by software
(2) Stop count
(3) Start count
(4) Stop count
Start count
Reload
Set to “1” by software
Cleared to “0” by software