The recommended implementation is to divide the VCC plane into two sections. The digital section
supplies power to the digital VCC pin, and to the external components. The analog section supplies
power to VCCH, VCCT, and VCCR pins of the LXT980. The break between the two planes should
run under the device. In designs with more than one LXT980, a single continuous analog VCC
plane can be used to supply them all.
The digital and analog VCC planes should be joined at one or more points by ferrite beads. The
beads should produce at least a 100
impedance at 100 MHz. The beads should be placed so that
current flow is evenly distributed. The maximum current rating of the beads should be at least
150% of the current that is actually expected to flow through them. Each LXT980 draws a
maximum of 500 mA from the analog supply so beads rated at 750 mA should be used. A bulk cap
(2.2 -10
μ
F) should be placed on each side of each ferrite bead to stop switching noise from
traveling through the ferrite.
In addition, a high-frequency bypass cap (.01
μ
f) should be placed near each analog VCC pin.
3.1.2.1
Ground Noise
The best approach to minimize ground noise is strict use of good general design guidelines and by
filtering the VCC plane.
3.1.3
Power and Ground Plane Layout Considerations
Great care needs to be taken when laying out the power and ground planes. The following
guidelines are recommended:
Follow the guidelines in the
LXT980 Design and Layout Guide
for locating the split between
the digital and analog VCC planes.
Keep the digital VCC plane away from the TPOP/N and TPIP/N signals, away from the
magnetics, and away from the RJ-45 connectors.
Place the layers so that the TPOP/N and TPIP/N signals can be routed near or next to the
ground plane. For EMI reasons, it is more important to shield TPOP and TPIP/N.
3.1.3.1
Chassis Ground
For ESD reasons, it is a good design practice to create a separate chassis ground that encircles the
board and is isolated via moats and keep-out areas from all circuit-ground planes and active
signals. Chassis ground should extend from the RJ-45 connectors to the magnetics, and can be used
to terminate unused signal pairs (
Bob Smith
termination). In single-point grounding applications,
provide a single connection between chassis and circuit grounds with a 2kV isolation capacitor. In
multi-point grounding schemes (chassis and circuit grounds joined at multiple points), provide 2kV
isolation to the Bob Smith termination.
3.1.4
MII Terminations
Series termination resistors are recommended on all MII signals driven by the LXT980. The proper
value = nominal trace impedance minus 13
. If the nominal trace impedance is not known, use
55
.
相關(guān)PDF資料
PDF描述
LZ1030M Common Anode Diode Array
LZ1032AD Interface IC
LZ1032AM Interface IC
LZ1032AR Interface IC
LZ1132BD Interface IC
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
LXTON/H0 制造商:Red Lion Controls 功能描述:ANNUN LABELS, 1 LPAX LABEL: TON/H 制造商:Red Lion Controls 功能描述:1 LPAX LABEL TON/H
LXTON000 制造商:Red Lion Controls 功能描述:ANNUNCIATOR LABELS,1 LPAX LABEL: TON 制造商:Red Lion Controls 功能描述:1 LPAX LABEL TON
LXU/MIN0 制造商:Red Lion Controls 功能描述:ANNUN LABELS, 1 LPAX LABEL: U/MIN 制造商:Red Lion Controls 功能描述:1 LPAX LABEL U/MIN
LXUA0000 制造商:Red Lion Controls 功能描述:ANNUNCIATOR LABELS, 1 LPAX LABEL: UA 制造商:Red Lion Controls 功能描述:1 LPAX LABEL UA
LXV00000 制造商:Red Lion Controls 功能描述:ANNUNCIATOR LABELS, 1 LPAX LABEL: V 制造商:Red Lion Controls 功能描述:1 LPAX LABEL V