le0104fi01_reli-RP3
le010401_reli_e-01
■ RELIABILITY DATA
*This catalog contains the typical specication only due to the limitation of space. When you consider the purchase of our products, please check our specication.
For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs.
12. Terminal strength : bending
LA Type
No abnormality such as cut lead, or looseness.
CAL45 Type
LHL□□□
FBA/FBR
FL05□ Type
FL06BT Type
【Test Method and Remarks】
LA, CA : Suspend a weight of specied mass at the end of the terminals and incline the body through the angle of 90 degrees and return it to the initial position. This operation
is done over a period of 2-3 sec. Then second bend in the opposite direction shall be made.
Number of bends : Two times.
Nominal wire diameter tensile
φd (mm)
Bending force
(N)
Mass reference weight
(kg)
0.3<φd≦0.5
2.5
0.25
0.5<φd≦0.8
5
0.50
LH·FB : Suspend a weight of specied mass at the end of the terminals and incline the body through the angle of 90 degrees and return it to the initial position. This operation
is done over a period of 2-3 sec. Then second bend in the opposite direction shall be made.
Number of bends : Two times.
Nominal wire diameter tensile
φd (mm)
Bending force
(N)
Mass reference weight
(kg)
0.3<φd≦0.5
2.5
0.25
0.5<φd≦0.8
5
0.5
0.8<φd≦1.2
10
1.0
13. Insulation resisitance : between the terminals and body
LA Type
CAL45 Type
LHL□□□
100MΩ min.
FBA/FBR
FL05□ Type
FL06BT Type
【Test Method and Remarks】
LHL□□□ : Applied voltage : 500 VDC
Duration
: 60 sec.
14. Insulation resistance : between terminals and core
LA Type
CAL45 Type
LHL□□□
FBA/FBR
1MΩ min. (Other than materail code MA)
FL05□ Type
FL06BT Type
【Test Method and Remarks】
FBA·FBR : Applied voltage : 100 VDC
Duration
: 60±5 sec.
15. Withstanding : between the terminals and body
LA Type
CAL45 Type
LHL□□□
No abnormality such as insulation damage
FBA/FBR
FL05□ Type
FL06BT Type
【Test Method and Remarks】
LHL□□□ : Accoding to JIS C5102. 7. 1. 3 (C)
Metal global method
Applied voltage : 500 VDC
Duration
: 60 sec.
16. DC bias characteristic
LA Type
△L/L : Within ー10%
CAL45 Type
LHL□□□
FBA/FBR
FL05□ Type
FL06BT Type
【Test Method and Remarks】
LA, CA : Measure inductance with appliation of rated current using LCR meter to compare it with the initial value.
17. Body strength
LA Type
No abnormality as damage.
CAL45 Type
LHL□□□
FBA/FBR
No abnormality such as cracks on body.
FL05□ Type
FL06BT Type
【Test Method and Remarks】
LA
: Applied force : 30N
Duration
: 10 sec.
Speed
: Shall attain to specied force in 2 sec.
CAL45 : Applied force : 50N
Duration
: 10 sec.
Speed
: Shall attain to specied force in 2 sec.
FBA
: Applied force : 50±3N
Duration
: 30±1 sec.