le0104fi01_reli-RP1
le010401_reli_e-01
■ RELIABILITY DATA
*This catalog contains the typical specication only due to the limitation of space. When you consider the purchase of our products, please check our specication.
For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs.
1. Operating temperature Range
LA Type
ー25~+105℃
CAL45 Type
LHL□□□
FBA/FBR
ー25~+85℃
FL05□ Type
ー25~+105℃
FL06BT Type
【Test Method and Remarks】
LA·CA·FL : Including self-generated heat
LHL□□□ : Including self-generated heat
3. Rated current
LA Type
Within the specied tolerance
CAL45 Type
LHL□□□
FBA/FBR
FL05□ Type
FL06BT Type
【Test Method and Remarks】
LA, CA
: The maximum DC value having inductance within 10% and temperature incease within 40℃ (LA:20℃) by the application of DC bias.
LHL□□□ : The maximum DC value having inductance decrease within 10% (LHLC08, LHLC10:within 30%) and temperature increase within the following specied
temperature by the application of DC bias.
Reference temperature : 25℃ (LHL08, LHL10, LHL13)
: 30℃ (LHL16, LHLP□□)
: 40℃ (LHLC08, LHLC10)
FB
: No disconnection or appearance abnormality by continuous current application for 30 min. Change after the application shall be within ±20% of the initial value.
This is not guaranteed for electrial characteristics during current application.
FL
: The maximum DC value having temperature rise within specied value.
5. Inductance
LA Type
Within the specied tolerance
CAL45 Type
LHL□□□
FBA/FBR
FL05□ Type
Within the specied tolerance
FL06BT Type
【Test Method and Remarks】
LA, CA
: Measuring equipment : LCR meter (HP4285A + HP42851A or its equivalent)
Measuring frequency : Specied frequency
LHL□□□ : Measuring equipment : LCR meter (HP4285A+HP42851A or its equivalent)
LCR meter (HP4263A) or its equivalent (at 1KHz)
Measuring frequency : Specied frequency
FL05R□
: Measuring equipment : HP4262A or its equivalent
Measuring frequency : 1kHz
6. Q
LA Type
Within the specied tolerance
CAL45 Type
LHL□□□
FBA/FBR
FL05□ Type
FL06BT Type
【Test Method and Remarks】
LA : Measuring equipment : LCR meter (HP4285A + HP42851A or its equivalent)
Measuring frequency : Specied frequency
LHL□□□ (except LHLP) : Measuring equipment : LCR meter (HP4285A+HP42851A or its equivalent)
LCR meter (HP4263A) or its equivalent (at 1kHz)
Measuring frequency : Specied frequency
2. Storage temperature Range
LA Type
ー40~+85℃
CAL45 Type
LHL□□□
FBA/FBR
FL05□ Type
FL06BT Type
4. Impedance
LA Type
CAL45 Type
LHL□□□
FBA/FBR
Within the specied tolerance
FL05□ Type
FL06BT Type
Refer to individual specication
【Test Method and Remarks】
FB
: Measuring equipment : Impedance analyzer (HP4191A) or its equivalent
Measuring frequency : Specied frequency
FL06BT : Measuring equipment : 4291A (HP) or its equivalent
Measuring frequency : Specied frequency