1.0 Functional Description
(Continued)
3.
Diode 1, Diode 2, and Diode 3 Remote Temperature set
to 0C until the LM83 senses a diode present between
the D+ and D input pins.
Status Registers 1 and 2 set to 00h.
Configuration Register set to 00h; INT enabled and all
T_CRIT setpoints enabled to activate T_CRIT_A.
Local and all Remote T_CRIT set to 127C
4.
5.
6.
1.5 SMBus INTERFACE
The LM83 operates as a slave on the SMBus, so the
SMBCLK line is an input (no clock is generated by the LM83)
and the SMBData line is bi-directional. According to SMBus
specifications, the LM83 has a 7-bit slave address. Bit 4 (A3)
of the slave address is hard wired inside the LM83 to a 1.
The remainder of the address bits are controlled by the state
of the address select pins ADD1 and ADD0, and are set by
connecting these pins to ground for a low, (0) , to V
CC
for a
high, (1), or left floating (TRI-LEVEL).
Therefore, the complete slave address is:
A6
MSB
and is selected as follows:
A5
A4
1
A2
A1
A0
LSB
Address Select Pin State
LM83 SMBus
Slave Address
A6:A0 binary
001 1000
001 1001
001 1010
010 1001
010 1010
010 1011
100 1100
100 1101
100 1110
ADD0
0
0
0
TRI-LEVEL
TRI-LEVEL
TRI-LEVEL
1
1
1
ADD1
0
TRI-LEVEL
1
0
TRI-LEVEL
1
0
TRI-LEVEL
1
The LM83 latches the state of the address select pins during
the first read or write on the SMBus. Changing the state of
the address select pins after the first read or write to any de-
vice on the SMBus will not change the slave address of the
LM83.
1.6 TEMPERATURE DATA FORMAT
Temperature data can be read from the Local and Remote
Temperature, T_CRIT, and HIGH setpoint registers; and writ-
ten to the T_CRIT and HIGH setpoint registers. Temperature
data is represented by an 8-bit, two’s complement byte with
an LSB (Least Significant Bit) equal to 1C:
Temperature
Digital Output
Binary
0111 1101
0001 1001
0000 0001
0000 0000
1111 1111
1110 0111
1100 1001
Hex
7Dh
19h
01h
00h
FFh
E7h
C9h
+125C
+25C
+1C
0C
1C
25C
55C
1.7 OPEN-DRAIN OUTPUTS
The SMBData, INT and T_CRIT_A outputs are open-drain
outputs and do not have internal pull-ups. A “high” level will
not be observed on these pins until pull-up current is pro-
vided from some external source, typically a pull-up resistor.
Choice of resistor value depends on many system factors
but, in general, the pull-up resistor should be as large as
possible. This will minimize any internal temperature reading
errors due to internal heating of the LM83. The maximum re-
sistance of the pull up, based on LM83 specification for High
Level Output Current, to provide a 2.1V high level, is 30k
.
1.8 DIODE FAULT DETECTION
Before each external conversion the LM83 goes through an
external diode fault detection sequence. If a D+ input is
shorted to V
or floating then the temperature reading will
be +127 C, and its OPEN bit in the Status Register will be
set. If the T_CRIT setpoint is set to less than +127 C then
the D+ inputs RTCRIT bit in the Status Register will be set
which will activate the T_CRIT_A output, if enabled. If a D+
is shorted to GND or D, its temperature reading will be 0 C
and its OPEN bit in the Status Register will not be set.
L
www.national.com
10