參數(shù)資料
型號: L8150
廠商: 意法半導(dǎo)體
英文描述: Brushless motor predriver
中文描述: 無刷電機預(yù)驅(qū)動
文件頁數(shù): 27/37頁
文件大?。?/td> 573K
代理商: L8150
L8150
Precharge and hall effects filtering time description
27/37
Figure 17.
Startup sequence forced by FS comparator, supposing the motor rotating
too quickly
When the signal coming from the FS comparator has a falling edge, by default a zero-
crossing signal is generated and the logic waits for a Hall effect commutation and applies to
it a filtering time of T
PRECHARGE
= 400
μ
sec. If the motor is rotating too quickly the next Hall
effect commutation happens before the filtering time is elapsed: this causes the reset of the
filter and, in consequence, a new count for the filter time of 400
μ
sec. Until the motor is
rotating too quickly no Hall effect commutation is acquired by the logic, thus the logic outputs
force high impedance condition.
Only when the motor speed becomes lower than the speed necessary to obtain a
Tel/6>400
μ
sec the Hall effect commutations are filtered and acquired.
If no Hall effect commutation is acquired during a period of TelMax/6, a precharge function
will be done.
Depending on the last filtered Hall effect codification present in the logic and, also, on the
Hall effect codification having a duration longer than 400
μ
sec (because the Hall effect
codifications filtered have to be consecutive), the Hall effect commutations filtered using a
filter time of 400usec could be two or, more probably, three.
After this Hall effect commutations the logic outputs start applying the right pattern to the
motor windings.
The motor rotation direction is irrelevant, in fact this can influence only the kind of pattern
applied after the two or three filtered Hall effect commutation.
Let's consider a startup sequence forced by FS-Comparator, supposing the motor
rotating slowly.
When the signal coming from the FS comparator has a falling edge, the logic waits for a Hall
effect commutation for a period of time equal to TelMAX/6. If no Hall effect commutation
happens during this time, the behaviour is the one described in the previous section, when a
startup sequence with motor stopped is described.
Let's suppose that during the counting period of TelMAX/6 a Hall effect commutation is
detected. This commutation is filtered using 400usec. Considering the hypothesis done,
starting from the Hall effect commutation detection, no more commutation will be detected
FS
ZC
HALL BUS
FILTER TIME
PHASES
PHASES EXCITED
T
zc’’/576
T
zc’
Tel
U
MOTOR ROTATING TOO FAST
400 us
T
zc’’
400 us
T
zc’/576
T
zc’
400 us
相關(guān)PDF資料
PDF描述
L8202 MULTIFUNCTION ANALOG ASIC
L9222 CAP CER 470PF 3.15KVDC R3 RAD
L9230 SPI CONTROLLED H-BRIDGE
L9230DIE1 SPI CONTROLLED H-BRIDGE
L9230-DIE1 SPI CONTROLLED H-BRIDGE
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
L815PW 制造商:SUPERWORLD 制造商全稱:Superworld Electronics 功能描述:HIGH CURRENT MOLDED POWER INDUCTORS
L815PW-100MF 制造商:SUPERWORLD 制造商全稱:Superworld Electronics 功能描述:HIGH CURRENT MOLDED POWER INDUCTORS
L815PW-1R0MF 制造商:SUPERWORLD 制造商全稱:Superworld Electronics 功能描述:HIGH CURRENT MOLDED POWER INDUCTORS
L815PW-1R5MF 制造商:SUPERWORLD 制造商全稱:Superworld Electronics 功能描述:HIGH CURRENT MOLDED POWER INDUCTORS
L815PW-2R2MF 制造商:SUPERWORLD 制造商全稱:Superworld Electronics 功能描述:HIGH CURRENT MOLDED POWER INDUCTORS