參數(shù)資料
型號: KSZ8863FLLI
廠商: Micrel Inc
文件頁數(shù): 42/106頁
文件大?。?/td> 0K
描述: IC ETHERNET SWITCH 3PORT 48-LQFP
標準包裝: 250
控制器類型: 以太網(wǎng)開關控制器
接口: MII
電源電壓: 1.8V,2.5V,3.3V
工作溫度: -40°C ~ 85°C
安裝類型: 表面貼裝
封裝/外殼: 48-LQFP
供應商設備封裝: 48-LQFP(7x7)
包裝: 托盤
配用: 576-3866-ND - BOARD EVALUATION FOR KSZ8863FLL
其它名稱: 576-3750
Micrel, Inc.
KSZ8863MLL/FLL//RLL
January 27, 2014
4
Revision 1.5
Contents
Functional Diagram............................................................................................................................................................... 1
Applications........................................................................................................................................................................... 2
Pin Description and I/O Assignment ................................................................................................................................. 12
Pin Configuration ................................................................................................................................................................ 16
Functional Description ....................................................................................................................................................... 17
Functional Overview: Physical Layer Transceiver .......................................................................................................... 17
100BASE-TX Transmit ..................................................................................................................................................... 17
100BASE-TX Receive ...................................................................................................................................................... 17
PLL Clock Synthesizer...................................................................................................................................................... 17
Scrambler/De-scrambler (100BASE-TX Only) ................................................................................................................. 17
100BASE-FX Operation.................................................................................................................................................... 17
100BASE-FX Signal Detection ......................................................................................................................................... 18
100BASE-FX Far-End Fault ............................................................................................................................................. 18
10BASE-T Transmit.......................................................................................................................................................... 18
10BASE-T Receive ........................................................................................................................................................... 18
MDI/MDI-X Auto Crossover .............................................................................................................................................. 18
Straight Cable ............................................................................................................................................................ 19
Crossover Cable ........................................................................................................................................................ 20
Auto-Negotiation ............................................................................................................................................................... 21
LinkMD
Cable Diagnostics.............................................................................................................................................. 22
Access ....................................................................................................................................................................... 22
Usage......................................................................................................................................................................... 22
Functional Overview: Power Management....................................................................................................................... 22
Normal Operation Mode ................................................................................................................................................... 23
Energy Detect Mode ......................................................................................................................................................... 23
Soft Power Down Mode .................................................................................................................................................... 23
Power Saving Mode.......................................................................................................................................................... 23
Port based Power Down Mode ......................................................................................................................................... 23
Functional Overview: MAC and Switch ............................................................................................................................ 24
Address Lookup ................................................................................................................................................................ 24
Learning ............................................................................................................................................................................ 24
Migration ........................................................................................................................................................................... 24
Aging................................................................................................................................................................................. 24
Forwarding ........................................................................................................................................................................ 24
Switching Engine .............................................................................................................................................................. 27
MAC Operation ................................................................................................................................................................. 27
Inter Packet Gap (IPG) .............................................................................................................................................. 27
Back-Off Algorithm..................................................................................................................................................... 27
Late Collision ............................................................................................................................................................. 27
Illegal Frames ............................................................................................................................................................ 27
Full Duplex Flow Control............................................................................................................................................ 27
Half-Duplex Backpressure ......................................................................................................................................... 27
Broadcast Storm Protection....................................................................................................................................... 28
Port Individual MAC address and Source Port Filtering ............................................................................................ 28
MII Interface Operation ..................................................................................................................................................... 28
RMII Interface Operation .................................................................................................................................................. 29
MII Management (MIIM) Interface .................................................................................................................................... 32
Serial Management Interface (SMI).................................................................................................................................. 33
相關PDF資料
PDF描述
PIC16C505-04E/SL IC MCU OTP 1KX12 14SOIC
PIC16F676T-E/ST IC MCU FLASH 1KX14 W/AD 14TSSOP
PIC12LC509A-04I/MF IC MCU OTP 1KX12 LV 8DFN
PIC12LCE519-04/SM IC MCU OTP 1KX12 LV W/EE 8-SOIJ
PIC12CE518T-04I/SM IC MCU OTP 512X12 W/EE 8-SOIC
相關代理商/技術參數(shù)
參數(shù)描述
KSZ8863MLL 功能描述:以太網(wǎng) IC 3-Port Copper 10/100 Ethernet Switch with 1x MII Interface (Lead Free) RoHS:否 制造商:Micrel 產(chǎn)品:Ethernet Switches 收發(fā)器數(shù)量:2 數(shù)據(jù)速率:10 Mb/s, 100 Mb/s 電源電壓-最大:1.25 V, 3.45 V 電源電壓-最小:1.15 V, 3.15 V 最大工作溫度:+ 85 C 封裝 / 箱體:QFN-64 封裝:Tray
KSZ8863MLL-EVAL 功能描述:以太網(wǎng)開發(fā)工具 3-Port Copper 10/100 Ethernet Switch with 1x MII Interface - Evaluation Board RoHS:否 制造商:Micrel 產(chǎn)品:Evaluation Boards 類型:Ethernet Transceivers 工具用于評估:KSZ8873RLL 接口類型:RMII 工作電源電壓:
KSZ8863MLLI 功能描述:以太網(wǎng) IC 3-Port Copper 10/100 Ethernet Switch w/ 1x MII Interface (Industrial Grade) RoHS:否 制造商:Micrel 產(chǎn)品:Ethernet Switches 收發(fā)器數(shù)量:2 數(shù)據(jù)速率:10 Mb/s, 100 Mb/s 電源電壓-最大:1.25 V, 3.45 V 電源電壓-最小:1.15 V, 3.15 V 最大工作溫度:+ 85 C 封裝 / 箱體:QFN-64 封裝:Tray
KSZ8863RLL 功能描述:以太網(wǎng) IC 3-Port Copper 10/100 Ethernet Switch with 1x RMII Interface (Lead Free) RoHS:否 制造商:Micrel 產(chǎn)品:Ethernet Switches 收發(fā)器數(shù)量:2 數(shù)據(jù)速率:10 Mb/s, 100 Mb/s 電源電壓-最大:1.25 V, 3.45 V 電源電壓-最小:1.15 V, 3.15 V 最大工作溫度:+ 85 C 封裝 / 箱體:QFN-64 封裝:Tray
KSZ8863RLL-EVAL 功能描述:以太網(wǎng)開發(fā)工具 3-Port Copper 10/100 Ethernet Switch with 1x RMII Interface - Evaluation Board RoHS:否 制造商:Micrel 產(chǎn)品:Evaluation Boards 類型:Ethernet Transceivers 工具用于評估:KSZ8873RLL 接口類型:RMII 工作電源電壓: