8
I
I
R
R
A
A
D
D
K
K
3
3
1
1
LEDs D10, D11, and SW2, SW3, R28
At initial power on, LEDs D10 (Red) and D11 (Green) blink on and off at a fixed rate.
Rotating potentiometer R28 can change the blinking rate. Clockwise (CW) slows the
blinking rate and counterclockwise (CCW) increases the blinking rate. When R28 is near
the end position on CCW, both LEDs may look like they are on all the time because they
are blinking at a faster rate. The functions of D10, D11, SW2, SW3, and R28 are as follows:
Stand-alone Mode (Also referred as Manual mode):
- Green LED: Indicates the Hall sensors level, 3 hall sensors combined when the motor
rotates. If the motor shaft is rotated by hand, this LED will blink on and off.
- Red LED: In normal operation indicates the direction of rotation command. On for
forward, Off for reverse. It will blink on and off, if hardware over current fault condition
occurs (using the last downloaded parameters).
- SW2: This switch is used to toggle between Run and Stop.
- SW3: This switch is used to toggle between Forward and Reverse.
- R28: Used to control the Motor speed.
PC Mode (Also referred as GUI mode):
- Green LED: Indicates the Hall sensors level, 3 hall sensors combined when the motor
rotates. If the motor shaft is rotated by hand, this LED will blink on and off.
- Red LED: In normal operation indicates the direction of rotation command. On for
forward, Off for reverse. It will blink on and off if an over current fault condition occurs.
- SW2, SW3: They are not used in PC Mode. GUI command is used instead.
- R28: Not used with this mode.
Test Points (TP1 – TP5)
These test points are used for voltage and signal monitoring purposes.
TP1, TP2: For monitoring the +DC Bus and –DC Bus, respectively
TP3: Current Feedback signal.
TP4: +15V auxiliary power supply.
TP5: +5V auxiliary power supply.
Jumper (J2)
This is the reset jumper to the microcontroller. When shorted, it resets the microcontroller
and starts the firmware from beginning. This jumper is default to open.
Jumper (J3)
This jumper is connected across the diode of Opto-isolator, OP3. It allows the user to
externally apply an Opto-isolated PWM signal into the microcontroller for debugging
purposes.
相關(guān)PDF資料
PDF描述
IRAM136-0461G iMOTION⑩ Series 4A, 600V Plug N DriveTM Integrated Power Module for Energy Efficient Motor Drives
IRAMS06UP60B Plug N Drive Integrated Power Module for Appliance Motor Drive
IRAMS10UP60APBF Plug N Drive⑩ Integrated Power Module for Appliance Motor Drive
IRAMX16UP60B Integrated Power Hybrid IC for Appliance Motor Drive Applications. 16A, 600V with Internal Shunt Resistor
IRAMX20UP60A 20A, 600V with open Emitter Pins
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
IRADK-S10UP60 制造商:International Rectifier 功能描述:
IRAE410 制造商:MURATA 制造商全稱:Murata Manufacturing Co., Ltd. 功能描述:PYROELECTRIC INFRARED SENSORS IRA SERIES
IRA-E410 制造商:MURATA 制造商全稱:Murata Manufacturing Co., Ltd. 功能描述:PYROELECTRIC INFRARED SENSORS IRA SERIES
IRA-E410QW1 制造商:Murata Manufacturing Co Ltd 功能描述:PYROELECTRIC INFRARED SENSOR - Bulk
IRA-E410S1 制造商:MURATA 制造商全稱:Murata Manufacturing Co., Ltd. 功能描述:PYROELECTRIC INFRARED SENSORS IRA SERIES