Immunity to Environmental Conditions
Table 9: Mechanical stress
Test method
Standard
Test conditions
Status
Ca
Damp heat
steady state
IEC/DIN IEC 60068-2-3
MIL-STD-810D section 507.2
Temperature:
Relative humidity:
Duration:
40
2
C
93
+2/-3
%
56 days
Unit not
operating
Ea
Shock
(half-sinusoidal)
IEC/EN/DIN EN 60068-2-27
MIL-STD-810D section 516.3
Acceleration amplitude:
Bump duration:
Number of bumps:
50 g
n
= 490 m/s
2
11 ms
18 (3 each direction)
Unit
operating
Eb
Bump
(half-sinusoidal)
IEC/EN/DIN EN 60068-2-29
MIL-STD-810D section 516.3
Acceleration amplitude:
Bump duration:
Number of bumps:
25 g
n
= 245 m/s
2
11 ms
6000 (1000 each direction)
Unit
operating
Fc
Vibration
(sinusoidal)
IEC/EN/DIN EN 60068-2-6
MIL-STD-810D section 514.3
Acceleration amplitude:
0.35 mm (10...60 Hz)
5 g
n
= 49 m/s
2
(60...2000 Hz)
10...2000 Hz
7.5 h (2.5 h each axis)
Unit
operating
Frequency (1 Oct/min):
Test duration:
Kb
Salt mist, cyclic
(sodium chloride
NaCl solution)
IEC/EN/DIN IEC 60068-2-52
Concentration:
Duration:
Storage:
Storage duration:
Number of cycles:
5% (30
C)
2 h per cycle
40
C, 93% rel. humidity
22 h per cycle
3
Unit not
operating
Table 10: Temperature specifications, valid for air pressure of 800...1200 hPa (800...1200 mbar)
Temperature
Characteristics
T
A
Ambient temperature
1
T
C
Case temperature
T
S
Storage temperature
1
Standard -9
G
Conditions
Operational
min
–40
–40
–55
max
71
105
105
Unit
°
C
Non operational
1
MIL-STD-810D section 501.2 and 502.2
Table 11: MTBF
Values at specified
case temperature
Type
Ground benign
25
C
Ground fixed
25
C
Ground mobile
55
C
Device hours
Unit
55
C
MTBF
48 IMS 30-0503
-9G
927'229
331'251
179'831
272'260
n.a.
h
1
Statistical values based on an average of 4300 working hours per year and in general field use, over 2 years.
8/11