INDUSTRIALTEMPERATURERANGE
IDT74FCT2244AT/CT
FASTCMOSOCTALBUFFER/LINEDRIVER
3
Symbol
Parameter
Test Conditions(1)
Min.
Typ.(2)
Max.
Unit
VIH
Input HIGH Level
Guaranteed Logic HIGH Level
2
—
V
VIL
Input LOW Level
Guaranteed Logic LOW Level
—
0.8
V
IIH
Input HIGH Current(4)
VCC = Max.
VI = 2.7V
—
±1
μA
IIL
Input LOW Current(4)
VCC = Max.
VI = 0.5V
—
±1
μA
IOZH
High Impedance Output Current
VCC = Max.
VI = 2.7V
—
±1
μA
IOZL
(3-State Output Pins)(4)
VI = 0.5V
—
±1
II
Input HIGH Current(4)
VCC = Max., VI = VCC (Max.)
—
±1
μA
VIK
Clamp Diode Voltage
VCC = Min., IIN = –18mA
—
–0.7
–1.2
V
VH
Input Hysteresis
—
200
—
mV
ICC
Quiescent Power Supply Current
VCC = Max.
—
0.01
1
mA
VIN = GND or VCC
DC ELECTRICAL CHARACTERISTICS OVER OPERATING RANGE
FollowingConditionsApplyUnlessOtherwiseSpecified:
Industrial: TA = –40°C to +85°C, VCC = 5.0V ±5%
NOTES:
1. For conditions shown as Min. or Max., use appropriate value specified under Electrical Characteristics for the applicable device type.
2. Typical values are at VCC = 5.0V, +25°C ambient.
3. Not more than one output should be tested at one time. Duration of the test should not exceed one second.
4. The test limit for this parameter is ±5
μA at TA = -55°C.
Symbol
Parameter
Test Conditions(1)
Min.
Typ.(2)
Max.
Unit
IODL
OutputLOWCurrent
VCC = 5V, VIN = VIH or VIL, VOUT = 1.5V(3)
16
48
—
mA
IODH
Output HIGH Current
VCC = 5V, VIN = VIH or VIL, VOUT = 1.5V(3)
-16
-48
—
mA
VOH
Output HIGH Voltage
VCC = Min
IOH = –15mA
2.4
3.3
—
V
VIN = VIH or VIL
VOL
Output LOWVoltage
VCC = Min
IOL = 12mA
—
0.3
0.5
V
VIN = VIH or VIL
OUTPUT DRIVE CHARACTERISTICS