IBM13M32734BCA
32M x 72 2-Bank Registered SDRAM Module
Preliminary
IBM Corporation. All rights reserved.
Use is further subject to the provisions at the end of this document.
Page 14 of 24
19L7297.F38442A
4/99
Operating, Standby, and Refresh Currents
 (T
A
= 0 to +70
°
C, V
DD
= 3.3V
 ±
 0.3V)
Parameter
Symbol
Test Condition
Speed
-75A
Units Notes
Burst Operating Mode/Active Standby
I
CC4
/I
CC3
CKE
 ≥
 V
IH
(min), t
CK
 = min,
S0 - S3 =V
IH
(min)
3190
mA
1, 2, 3
Burst Operating Mode/Precharge Standby
I
CC4
/I
CC2
CKE
 ≥
 V
IH
(min), t
CK
 = min,
S0 - S3 =V
IH
(min)
3100
mA
1, 2, 3
Burst Operating Mode/Auto Refresh
I
CC4
/I
CC5
CKE
 ≥
 V
IH
(min), t
CK
 = min,
S0 - S3 =V
IH
(min)
5080
mA
1, 2, 3
Non-burst Operating Mode/Active Standby
I
CC1
/I
CC3
CKE
 ≥
 V
IH
(min), t
CK
 = min,
S0 - S3 =V
IH
(min)
2380
mA
1, 2, 3
Non-burst Operating Mode/Precharge Standby
I
CC1
/I
CC2
CKE
 ≥
 V
IH
(min), t
CK
 = min,
S0 - S3 =V
IH
(min)
2290
mA
1, 2, 3
Non-burst Operating Mode/Auto Refresh
I
CC1
/I
CC5
CKE
 ≥
 V
IH
(min), t
CK
 = min,
S0 - S3 =V
IH
(min)
4270
mA
1, 3
Active Standby/Active Standby
I
CC3
/I
CC3
CKE
 ≥
 V
IH
(min), t
CK
 = min,
S0 - S3 =V
IH
(min)
1750
mA
3
Active Standby/Precharge Standby
I
CC3
/I
CC2
CKE
 ≥
 V
IH
(min), t
CK
 = min,
S0 - S3 =V
IH
(min)
1660
mA
3
Active Standby/Auto Refresh
I
CC3
/I
CC5
CKE
 ≥
 V
IH
(min), t
CK
 = min,
S0 - S3 =V
IH
(min)
3640
mA
1, 3
Precharge Standby/Precharge Standby
I
CC2
/I
CC2
CKE
 ≥
 V
IH
(min), t
CK
 = min,
S0 - S3 =V
IH
(min)
1570
mA
3
Precharge Standby/Auto Refresh
I
CC2
/I
CC5
CKE
 ≥
 V
IH
(min), t
CK
 = min,
S0 - S3 =V
IH
(min)
3550
mA
1, 3
Auto Refresh/Auto Refresh
I
CC5
/I
CC5
CKE
 ≥
 V
IH
(min), t
CK
 = min,
S0 - S3 =V
IH
(min)
5530
mA
1, 3
Active Standby Power Down/Active Standby Power Down
I
CC3p
/I
CC3p
CKE
 ≤
 V
IL
(max), t
CK
 = min,
S0 - S3 =V
IH
(min)
562
mA
3
Active Standby Power Down/Precharge Standby Power Down
I
CC3p
/I
CC2p
CKE
 ≤
 V
IL
(max), t
CK
 = min,
S0 - S3 =V
IH
(min)
454
mA
3
Precharge Standby Power Down/Precharge Standby Power
Down
I
CC2p
/I
CC2p
CKE
 ≤
 V
IL
(max), t
CK
 = min,
S0 - S3 =V
IH
(min)
346
mA
3
Precharge Standby Non-power Down/Precharge Standby Non-
power Down (NO CLOCK)
I
CC2S
/I
CC2S
CKE
 ≥
 V
IH
(min), t
CK
 = Infinity,
S0 - S3 =V
IH
(min)
195
mA
3
Precharge Standby Power Down/Precharge Standby Power
Down (NO CLOCK)
I
CC2PS
/I
CC2PS
CKE
 ≥
 V
IH
(min), t
CK
 = Infinity,
S0 - S3 =V
IH
(min)
51
mA
3
1. These parameters depend on the cycle rate and are measured with the cycle determined by the minimum value of t
CK
and t
RC
.
Input signals are changed once during t
CK
(min). t
CK
(min) = 7.5ns.
2. The specified values are obtained with the output open.
3. These parameters and symbols refer to a combination of physical bank 0/physical bank 1.
Discontinued (8/99 - last order; 12/99 - last ship)