6. Timer G operation modes
Timer G operation modes are shown in table 9-13.
Table 9-13 Timer G Operation Modes
Operation Mode
Reset Active
Sleep
Watch
Subactive Subsleep
Standby
Module
Standby
TCG
Input capture
Reset Functions
*
Functions
*
Functions/
halted
*
Functions/
halted
*
Functions/
halted
*
Halted
Halted
Interval
Reset Functions
*
Functions
*
Functions/
halted
*
Functions/
halted
*
Functions/
halted
*
Halted
Halted
ICRGF
Reset Functions
*
Functions
*
Functions/
halted
*
Functions/
halted
*
Functions/
halted
*
Held
Held
ICRGR
Reset Functions
*
Functions
*
Functions/
halted
*
Functions/
halted
*
Functions/
halted
*
Held
Held
TMG
Reset Functions
Held
Held
Functions
Held
Held
Held
Note:
*
When
w/4 is selected as the TCG internal clock in active mode or sleep mode, since
the system clock and internal clock are mutually asynchronous, synchronization is
maintained by a synchronization circuit. This results in a maximum count cycle error of
1/
(s). When
w/4 is selected as the TCG internal clock in watch mode, TCG and the
noise canceler operate on the
w/4 internal clock without regard to the
subclock
(
w/8,
w/4,
w/2). Note that when another internal clock is selected, TCG and the
noise canceler do not operate, and input of the input capture input signal does not result
in input capture.
To operate the timer G in subactive mode or subsleep mode, select
w/4 as the TCG
internal clock and
w/2 as the subclock
. Note that when other internal clock is
selected, or when
w/8 or
w/4 is selected as the subclock
SUB
, TCG and the noise
canceler do not operate.
9.5.5
Application Notes
1. Internal clock switching and TCG operation
Depending on the timing, TCG may be incremented by a switch between difference internal clock
sources. Table 9-14 shows the relation between internal clock switchover timing (by write to bits
CKS1 and CKS0) and TCG operation.
When TCG is internally clocked, an increment pulse is generated on detection of the falling edge
of an internal clock signal, which is divided from the system clock (
) or subclock (
w). For this
reason, in a case like No. 3 in table 9-14 where the switch is from a high clock signal to a low
clock signal, the switchover is seen as a falling edge, causing TCG to increment.